Gira 5431 00 Operating Instructions Manual page 6

Wireless dimming actuator, 4-gang.
Table of Contents

Advertisement

Wireless dimming actuator, 4-gang
Figure 4: Connection example with two parallel outputs each
Do not connect any LED lamps or compact fluorescent lamps to outputs switched in par-
allel.
Do not connect electronic and inductive Transformers together to outputs switched in par-
allel.
Connect loads as shown in the wiring example (Figure 4).
Presetting the operating mode
Each load output has an operating mode switch with which the dimming principle is set.
Switch position
PC
R,L,C
Universal
HV-|LED leading edge
phase control
HV-{LED trailing edge
phase control
32578622
10867484
Figure 5: Operating mode switch
Function/connectable loads
Dimming principle and parameter set with eNet Server.*)
Automatic calibration to the load, dimming principle, leading
edge phase control or trailing edge phase control. Connec-
tion of incandescent lamps, HV halogen lamps, electronic
transformers with halogen or LED lamps or dimmable induct-
ive transformers with halogen or LED lamps.
Setting for incandescent lamps, HV halogen lamps, elec-
tronic transformers with halogen or LED lamps that can be
dimmed according to the trailing edge phase control principle
or dimmable HV-LED or compact fluorescent lamps that can
be dimmed according to the leading edge phase control prin-
ciple. The connection of inductive transformers is not permit-
ted.
Setting for incandescent lamps, HV halogen lamps, elec-
tronic transformers with halogen or LED lams that can be
dimmed according to the trailing edge phase control prin-
01.10.2019
6 / 19

Advertisement

Table of Contents
loading

Table of Contents