Inspecting The Unit; Performing A Visual Inspection - Henny Penny FlexFusion GAS PLATINUM COMBI Series Operating Manual

Table of Contents

Advertisement

Cleaning and caring for the unit
Prerequisite Unit switched off

7.14 Inspecting the unit

7.14.1 Performing a visual inspection

NOTICE
98
a
b
c
Image: Air diverter fasteners on countertop and pedestal units
a Air diverter
b Upper fastener
Opening the air diverter
1. Remove the left support rack; present only in size 6 and size 10.
2. Loosen the upper fastener.
3. Loosen the lower fastener.
4. Loosen the center fastener; present only in size 20.
5. Swing the air diverter toward the back wall.
Swinging back the air diverter
1. Swing back the air diverter along the side wall.
2. Close the upper fastener.
3. Close the lower fastener.
4. Close the center fastener; present only in size 20.
5. Check the fasteners.
6. Insert the left support rack; present only in size 6 and size 10.
Risk of property damage from improper inspection
• Inspect in accordance with the inspection intervals.
• Have inspections performed by a capable user.
• In the event of damage or signs of wear, contact customer service immedi-
ately and stop using the unit.