Installing the unit

5.5 Inspecting the recirculation hood filter

Prerequisite Unit dead

5.6 Fastening the unit to the floor

5.6.1 Securing the unit to prevent tipping

WARNING
20
Image: Recirculation hood filter
a Condensation baffle
b Filter drawer
c Air outlet
d Recirculation hood
Step ladder set up securely
1. Remove the filter drawer with the filter.
2. Unhook the condensation baffle.
3. Check that the air filter is located correctly in the holder.
Make sure that the filter is in the correct position.
The air filter lies in the holders.
4. Hook the condensation baffle back in.
5. Check that the yellow filter mat is firmly located in the filter drawer.
6. Push the filter drawer in as far as the end stop.
7. Fill out the start-up operation report.
Risk of accident from insufficient fastening
Unit can tip over
• Depending on the unit type, suitable measures must be taken to fasten the
unit to the floor.
• Comply with the requirements for the condition of the floor.
• Comply with the requirements for the means of fastening.
Installation instructions
d
c
b
a
h
g
e Vapor inlet
f Filter mat (yellow)
g Air filter
h Activated charcoal filter
f
e