A tap with a metric R3/4 thread is
required for connection to the water
supply.
The solenoid valve is located at the
back of the appliance at the bottom. It
also has a metric R3/4 threaded
connection.
Unscrew the safety cap from the
nut on the straight end of the
hose .
Connect this nut to the tap
using the tool supplied. Tighten
the nut by turning it clockwise until
the maximum torque is reached and
the tool is over-torqued.
Briefly open the tap to vent the
pipework, and fill the pipework with
water. Place the end of the hose in a
bucket when doing this.
Pull off the cover on the solenoid
valve .
Push the nut over the angled end
of the hose as far as it will go,
holding the nut securely.
Moisten the seal , then press the
seal into the nut.
The seal should lie flush with the angled
end of the hose and held lightly in
position.
Take care not to damage the
thread in the solenoid valve.
Position the nut carefully and screw it
into position.
Connect the hose by the angled end
to the solenoid valve.
Tighten the nut with the tool
supplied by turning it clockwise
until the maximum torque is reached
and the tool is over-torqued.
Slowly open the tap and check the
entire water system for leaks.
Fold in the tab on the tool and
secure the tool to the stainless steel
hose for safe-keeping.
Installation
71