Installation - EdilKamin WINDO2 75 Installation, Use And Maintenance Manual

Table of Contents

Advertisement

Assembly of internal refractories
Assembly of internal refractories
The fi replace is delivered without the internal
The fi replace is delivered without the internal
refractories installed to prevent breakages.
refractories installed to prevent breakages.
To insert them (fi gure below):
To insert them (fi gure below):
• •
unscrew (4 front screws and 1 side screw) the
unscrew (4 front screws and 1 side screw) the
fi xing plate A;
fi xing plate A;
• •
insert the pieces on the bottom (B, C, C, B, D) and
insert the pieces on the bottom (B, C, C, B, D) and
side D;
side D;
• •
remount and screw plate A;
remount and screw plate A;
• •
fi t the defl ector E
fi t the defl ector E
screw
detailed
view

INSTALLATION

Self-closing door
Self-closing door
The fi replace is delivered with the door balanced, that
The fi replace is delivered with the door balanced, that
is, it does not drop automatically once raised.
is, it does not drop automatically once raised.
To make the door self-closing, one or more plates (P)
To make the door self-closing, one or more plates (P)
must be applied to the inner frame for the door.
must be applied to the inner frame for the door.
To access the inner frame for the door, remove the fl ap
To access the inner frame for the door, remove the fl ap
located on the fi replace's casing.
located on the fi replace's casing
without plates (standard) with plates (added
NOT self-closing
INTERNAL VIEW OF THE PLATES
ON THE DOOR FRAME
screw
detailed
view
during the installation
phase)
self-closing
P
9