4.4.2.3
Lubrication
Damage to the gear unit due to overheating of the components
Inadequate lubrication of the components may lead to damage to the gear unit due to over-
heating.
CAUTION
• Calculate the usable life of the lubricant used
• Relubricate all relevant components as required
4.4.2.3.1
Calculating the usable life of the lubricant
To calculate the usable life of your lubricant, proceed as follows:
• Measure the temperature at the center of the housing in maximum operating state. The gear unit has
reached thermal steady state when the temperature increase no longer exceeds 2 °C per hour.
Damage to the gear box due to exceeding of the maximum permitted temper-
ature
If the maximum permitted temperature for the gear unit is exceeded, the gear unit may be-
CAUTION
come damaged due to overheating.
• Ensure correct and adequate cooling, positioning and installation of the gear unit, in or-
der to avoid exceeding the maximum permitted temperature.
• Switch off the machine / system as soon as the limit value is reached and the maximum
temperature is exceeded.
• Add 10 °C to the measured temperature.
• Now determine the usable life of the lubricant based on the table below.
4.4.3

Commissioning after maintenance

• Clean the gear unit externally.
• Attach all safety devices.
• Perform a test run before releasing the gear unit again for operation.