Mounting Without Alignment Laser; Horizontal Mounting (Travel Axis) Without Alignment Laser - Leuze electronic DDLS 508 Operating Instructions Manual

Optical data transmission for 100 mbit/s ethernet version f0
Hide thumbs Also See for DDLS 508:
Table of Contents

Advertisement

You will achieve greater flexibility during basic installation if you mount the devices on C profile
rails.
 Detach the contour of the optical window from the drilling template along the perforation (see figure 4.2).
 Affix the removed drilling template to the optical window of the mobile device using the supplied self-
adhesive labels.
 Switch on the alignment laser of the stationary device.
Activate the LAS (Alignment laser) operating mode to switch on the alignment laser (see chapter 6.1).
 Move the mobile device on the lifting axis in manual operation to maximum distance.
 Align the stationary device using the alignment screws (see figure 3.1, point 11 and point 12) and, if
necessary, using the C profile rails.
The target spot of the alignment laser must be in the center of the drilling template on the mobile device.
 Move the mobile device on the lifting axis in manual operation to minimum distance.
The target spot of the alignment laser must not extend beyond the outer ring of the drilling template on
the mobile device.
If necessary, realign the stationary device.
 Switch off the alignment laser of the stationary device.
Activate the AUT (Automatic) operating mode to switch off the alignment laser (see chapter 6.1).
 Affix the detached drilling template to the optical window of the stationary device using the supplied self-
adhesive labels.
 Switch on the alignment laser of the mobile device.
Activate the LAS (Alignment laser) operating mode to switch on the alignment laser (see chapter 6.1).
 Move the mobile device on the lifting axis in manual operation to maximum distance.
 Align the mobile device using the alignment screws (see figure 3.1, point 11 and point 12) and, if neces -
sary, using the C-profile rails.
The target spot of the alignment laser must be in the center of the drilling template on the stationary
device.
 Move the mobile device on the lifting axis in manual operation to minimum distance.
The target spot of the alignment laser must not extend beyond the outer ring of the drilling template on
the stationary device.
If necessary, realign the mobile device.
 Switch off the alignment laser of the mobile device.
Activate the AUT (Automatic) operating mode to switch off the alignment laser (see chapter 6.1).
 Remove the drilling template from the stationary device.
This concludes the mounting of the devices in the lifting axis.
Further procedure:
• Perform the fine adjustment for the lifting axis (see chapter 6.2 "Fine adjustment").
4.3

Mounting without alignment laser

 Observe the mounting instructions (see chapter 4.1 "Mounting instructions").
You will achieve greater flexibility during basic installation if you mount the devices on C profile
rails.
4.3.1

Horizontal mounting (travel axis) without alignment laser

 Depending on mechanical conditions, mount the stationary or mobile device with four M5 screws via the
fastening holes in the mounting plate.
 Move the mobile device as close as possible to the stationary device.
Leuze electronic
DDLS 508
Mounting
27

Advertisement

Table of Contents
loading