Leuze electronic DDLS 508 Operating Instructions Manual page 13

Optical data transmission for 100 mbit/s ethernet version f0
Hide thumbs Also See for DDLS 508:
Table of Contents

Advertisement

1
1
2
3
4
5
6
7
Figure 3.5:
Operating state LEDs in the control panel
Table 3.2:
LED
Color
PWR
---
Green
Green
Red
Red
TMP
---
Orange
Red
Leuze electronic
2
3
4
PWR – Supply voltage (Power)
TMP – Temperature warning/error
LSR – Laser prefailure message
FRE - Indicates the preselected transmission frequency
OLK – Optical link
ERL – Error Link
LINK – M12 cable-connected link
Meaning of the operating state indicators
State
Description
OFF
No supply voltage (see chapter 7.1)
Flashing
Device is being initialized
Continuous
Data transmission path ready
light
Flashing
Warning set (see chapter 7.1)
Continuous
Device error (see chapter 7.1)
light
OFF
Operating temperature in the specified working range
Continuous
light
Continuous
light
5
6
7
• Supply voltage connected
• Initialization running
• No data sent or received
• Initialization finished
• No green and orange LEDs in SIGNAL QUALITY indicator
• The optical link is interrupted.
• The laser diode of the transmitter is defective.
• The function of the device is limited.
The displays of the other operating state LEDs may provide
information on the cause of the error.
• Warning: The operating temperature is above or below the
specified working range by a maximum of 5 °C (see
chapter 7.1).
• Data transmission remains active.
• The operating temperature is above or below the specified
working range by more than 5 °C (see chapter 7.1).
• The operating time outside of the permissible operating tem -
perature is detected by the device.
• Data transmission remains active.
DDLS 508
Device description
14