Table 6.1:
Operating mode
AUT
Automatic
MAN
Manual
ADJ
Aligning
(Adjust)
Leuze electronic
Operating modes
Description
Standard operating mode for data transmission. When the supply voltage
is applied, the device starts in the AUT operating mode.
Note:
Operating modes that were active before the device was switched off are
no longer active after the device is switched back on.
Operating mode for fine adjustment of the devices via SHA (see
chapter 6.2.2).
Data transmission switches off as soon as no green LEDs in the
SIGNAL QUALITY indicator illuminate.
Note:
The AUT LED switches off if the MAN operating mode is activated.
Operating mode for fine adjustment of the devices via SHA (see
chapter 6.2.2).
• Data transmission to the connected participants is interrupted.
• The received signal level (SIGNAL QUALITY indicator) of the
second device is transmitted to the SIGNAL QUALITY indicator of
the first device.
The quality of the fine adjustment is read directly on the device
(SIGNAL QUALITY indicator) on which the fine adjustment is perfor -
med via the alignment screws.
Notes:
• The AUT LED switches off if the ADJ operating mode is activated.
• The MAN LED switches off if the ADJ operating mode is activated.