Electrical Connection; Overview; Power (Supply Voltage / Switching Input And Switching Output) - Leuze electronic DDLS 508 Operating Instructions Manual

Optical data transmission for 100 mbit/s ethernet version f0
Hide thumbs Also See for DDLS 508:
Table of Contents

Advertisement

5

Electrical connection

5.1

Overview

The electrical connection of the device is performed using M12 connectors.
2
1
2
Figure 5.1:
Position and designation of the M12 connections
CAUTION
Safety notices!
 Before connecting the device, be sure that the supply voltage agrees with the value printed on the
name plate.
 Only have the electrical connection performed by certified electricians.
 Ensure that the functional earth (FE) is connected correctly.
Fault-free operation is only guaranteed if the functional earth is connected properly.
 If faults cannot be rectified, take the device out of operation. Protect the device from accidentally being
started.
NOTICE
UL applications
 For UL applications, use is only permitted in Class 2 circuits in accordance with the NEC (National
Electric Code).
NOTICE
Protective Extra Low Voltage (PELV)
 The device is designed in accordance with safety class III for supply with PELV (Protective Extra-Low
Voltage).
5.2

POWER (supply voltage / switching input and switching output)

5-pin, M12 plug (A-coded) for connecting to POWER.
5
2
1
3
4
Figure 5.2:
Pin assignments for POWER connection
Leuze electronic
1
POWER
BUS
FE
DDLS 508
Electrical connection
35