Operating mode
LAS
Laser Adjustment System
(Alignment laser)
LLC
Link Loss Counter
(interruption diagnostics)
FRE
Display of the preselected
transmission frequency (F1
or F2)
Activating the operating mode
 Select the desired operating mode by briefly pressing the operating mode selector switch [MODE].
Repeatedly pressing the operating mode selector switch [MODE] selects the next operating mode, rol -
ling from top to bottom.
The LED of the selected operating mode flashes.
 Activate the selected operating mode.
• Press the operating mode selector switch [MODE] for approx. two seconds until the LED of the
selected operating mode illuminates continuously.
• Release the operating mode selector switch [MODE] to activate the selected operating mode.
The LED of the selected operating mode illuminates continuously.
Data transmission remains active while changing the operating mode.
Exception: operating mode ADJ. After activating the ADJ operating mode, data transmission of
process data is interrupted.
Deactivating the operating mode
 Select a new operating mode by repeatedly pressing the operating mode selector switch [MODE] for a
short time.
Leuze electronic
Description
Operating mode for activation/deactivation of the alignment laser (see
chapter 4.2).
Notes:
• The LAS operating mode can only be activated for devices with
alignment laser.
• If the LAS operating mode is activated for an actively transmitting
data transmission path, data transmission remains active.
• The AUT LED (green) illuminates simultaneously with the LAS LED
(green).
• In the LAS operating mode, the MAN, ADJ and LLC operating
modes are not to be activated.
Operating mode for activation/deactivation of interruption diagnostics. If
LLC is activated, an interruption of the optical link is displayed via the
LLC LED (see table 3.1).
Notes:
• The LLC LED illuminates red even if the optical link is restored fol -
lowing an interruption.
• The AUT LED (green) illuminates simultaneously with the LLC LED
(green or red).
• To reactivate LLC following an interruption of the optical link, the LLC
operating mode must be reset (see chapter "Activating the operating
mode").
• In the LLC operating mode, the MAN, LAS and ADJ operating
modes are deactivated.
For a given transmission path, the devices must be set to different trans -
mission frequencies during commissioning.
Transmission frequency F1 or F2 is configured with the operating mode
selector switch [Mode] via the FRE LED.
• FRE LED off: Transmission frequency F1 active
• FRE LED illuminates: Transmission frequency F2 active (factory set -
ting)
Note:
• The transmission path is correctly configured if the FRE LED on one
device illuminates and does not illuminate on the opposing device.