The LED of the newly selected operating mode flashes.
Activate the newly selected operating mode.
• Press the operating mode selector switch [MODE] for approx. two seconds until the LED of the newly
selected operating mode illuminates continuously.
• Release the operating mode selector switch [MODE] to activate the newly selected operating mode.
The previously activated operating mode is deactivated.
The LED of the newly selected operating mode illuminates continuously.
If, while selecting a new operating mode, the operating mode selector switch [MODE] is not
pressed for a longer period of time (> 10 s), the previously activated operating mode remains ac -
tive.
6.2
Fine adjustment
6.2.1
General procedure
Fine adjustment of the data transmission must be carried out after installation.
Prerequisites:
• The devices are mounted mutually opposing one another, are electrically connected and are roughly
aligned (see chapter 4 "Mounting").
• The devices are opposite one another at a close distance (> 1 m). The SIGNAL QUALITY indicator
shows at least one or two green LEDs on both devices.
NOTICE
Cover reflectors of laser measurement systems during fine adjustment!
Cover the reflectors of a laser measurement system that is mounted next to the optical data transcei -
ver during fine adjustment.
Leuze electronic
DDLS 508
Starting up the device
41