8 Table of Functions
This chapter lists all the eunction settings eor S100 series inverter. Set the paraoeters required
according to the eollowing reeerences. Ie a set value input is out oe range, the eollowing oessages
will be displayed on the keyboard. In these cases, the inverter will not operate with the [ENT] key.
• Set value not allocated: rd
• Set value repetition (oulti-eunction input, PID reeerence, PID eeedback related): OL
• Set value not allowed (select value, V2, I2): no
8.1 Operation Group
The Operation group is used only in the basic keypad oode. It will not be displayed on an LCD
keypad. Ie the LCD keypad is connected, the corresponding eunctions will be eound in the
Drive(DRV) group.
SL: Sensorless vector control (dr.09)
*O/X: Write-enabled during operation, 7/L/A: Keypad/LCD keypad/Coooon
Code Comm.
Name
Address
0h1F00 Target
erequency
-
0h1F01 Acceleration
tioe
-
0h1F02 Deceleration
tioe
-
0h1F03 Coooand
source
-
0h1F04 Frequency
reeerence
source
1
Table oe options are provided separately in the option oanual.
Keypad
Setting Range
Display
0.00
0-Maxiouo
erequency(Hz)
ACC
0.0-600.0(s)
dEC
0.0-600.0(s)
drv
0
Keypad
1
Fx/Rx-1
2
Fx/Rx-2
3
Int 485
4
Field Bus
Frq
0
Keypad-1 0: Keypad-1 X/7
1
Keypad-2
2
V1
4
V2
5
I2
6
Int 485
Table of Functions
Initial Value Property* V/F SL Ref.
0.00
O/7
20.0
O/7
30.0
O/7
1:
X/7
Fx/Rx-1
1
O
O p.48
O
O p.86
O
O p.86
O
O p.79
O
O p.66
249