6. Basic setup procedures

6.2 Hang up a MiSPHERE string

Necessary parts
Two long safety cables per string.
One long MiSPHERE primary cable per string.
How to hang up a MiSPHERE string ?
1. Provide the second last MiSPHERE unit with a long safety cable (S1).
Note: There may not be a short link cable connected on the male input socket of the MiSPHERE unit. Otherwise it's impossible
to attach the long safety cable with the safety eye lid.
2. Connect a short link cable upon the second last MiSPHERE unit.
3. Connect the last MiSPHERE unit with the previous installed short link cable.
4. Provide the last MiSPHERE unit with a long safety cable (S2).
Note: There may not be a primary cable connected on the male input socket of the MiSPHERE unit. Otherwise it's impossible
to attach the long safety cable with the safety eye lid.
5. Connect a long MiSPHERE primary cable (P) with the male input socket of the last MiSPHERE unit.
S1
Image 6-7
6. Suspend the MiSPHERE string by attaching the other ends of both long safety cables (S1 and S2) ) to e.g. a truss installation
(T). Adjust the height of the MiSPHERE string by shorten the long safety cables.
7. Strap up the primary cable (P).
34
S2
R5976941 MISPHERE 03/01/2006
P