Using energy-efficient LED backlights, Barco’s Coronis 5MP LED Display is as low in power consumption as it is high in brightness. Additionally, Barco’s LED backlights are mercury-free, produce less heat, and last longer. This allows Barco to guarantee a 5-year backlight warranty.
• USB cable If you ordered a Barco display controller, it’s also in the box together with its accessories. A dedicated user guide is available on the documentation disc. Keep your original packaging. It is designed for this display and is the ideal protection during transport and storage.
Page 7
1. Welcome! 6. Power status LED - Off: Display not powered, or display operational but power LED function disabled in OSD (see "Power LED", page 17) - Steady white: Display operational - Slow blinking amber: Display in suspend mode (requires DPMS mode to be enabled in the OSD menu, see "DPMS mode", page 18) - Fast blinking amber: Display in standby mode (requires DPMS mode to be enabled in the OSD menu, see "DPMS mode", page 18)
Page 8
1. Welcome! K5902120 CORONIS 5MP LED DISPLAY 18/01/2018...
Prior to installing your Coronis 5MP LED Display and connecting all necessary cables, make sure to have a suitable display controller physically installed in your computer. If you are using a Barco display controller, please consult the user guide delivered with it to do this.
2. Installation The display must be in its highest position before it can be properly pivoted. ARNING Store the foot lock clip in the storage hole in case the display needs to be transported later. Image 2-3 If, after installing the display of the system, you change the panel orientation while an image is on the screen, the result depends on the graphic board and the resolution of the image.
Page 11
2. Installation 2. Connect a video source from your workstation to the corresponding video inputs on the display. Caution: Connect only one of the two video inputs. Connecting both inputs simultaneously will result in driver errors. Image 2-5 3. Connect the workstation’s USB host to the USB upstream connector on the display if you want to make use of QAWeb or any of the display USB downstream connectors (e.g.
2. Installation 5. Route all cables through the cable duct in the stand of your display. For better strain-relief and shield- ing of the cables, fix the cables with the cable straps at the inside of the connector compartment. Image 2-8 6.
Page 13
2. Installation Use an arm that is approved by VESA (according to the VESA 100 mm stan- ARNING dard). Use an arm that can support the weight of the display. Refer to the technical specifica- tions of this display for the applicable weight. Overview The panel, standard attached to the tilt &...
Your Coronis 5MP LED Display will be running in a basic video mode at a default refresh rate when first time starting up. If you are using a Barco display controller, please con- sult the user guide delivered with it to install the drivers, software and documentation.
LCD displays use technology based on pixels. As a normal tolerance in the manufacturing of the LCD, a limited number of these pixels may remain either dark or permanently lit, without affecting the diagnostic performance of the product. To ensure optimal product quality, Barco applies strict selection criteria for its LCD panels.
The ’MediCal QAWeb’ system offers online service for high-grade Quality Assurance, providing maximum diagnostic confidence and uptime. Barco recommends to install MediCal QAWeb Agent and apply the default QAWeb policy at least. This policy includes calibration on regular intervals. Connecting to MediCal QAWeb Server offers even more possibilities.
3. Daily operation Bringing up the OSD menus How to bring up the OSD menus The OSD menu allows you to configure different settings to make your Coronis 5MP LED Display fit your needs within your working environment. Also, you can retrieve general information about your display and its current configuration settings through the OSD menu.
When the display is in power on mode and the OSD menu is not shown, I-Luminate can be activated by touching the I-luminate/left key. Unlike other Barco products, especially designed for tomography, in the MDCG-5221, I-Luminate supports one mode: Full-screen luminance boost.
4. Advanced operation 4. ADVANCED OPERATION OSD menu language About the OSD menu language By default, the OSD menu comes up in English. However, there’s a wide range of other languages avail- able for the OSD menu of your Coronis 5MP LED Display. To change the language of the OSD menu: 1.
4. Advanced operation To enable/disable the power LED: 1. Bring up the OSD main menu. 2. Navigate to the Configuration > User Interface > Indicator Lights menu. 3. Enter the Power Status submenu. 4. Select Enabled/Disabled as desired and confirm. Key indicator lights About the key indicator lights By default, after lighting up, the key indicator lights will dim again if no further actions are taken within the...
4. Advanced operation Barco recommends setting DPMS activation after 20 minutes of non-usage. When DPMS mode is enabled on your display, an additional OSD power saving function becomes available: hibernate. Please refer to "Hibernate", page 19 for more information on hibernation and how to enable this function.
4. Advanced operation I-Luminate default mode About the I-Luminate default mode The I-Luminate default mode defines the default activated mode during the I-Luminate boost. This mode Screen The boost mode is applied on the screen display. To enable/disable I-Luminate: 1. Bring up the OSD main menu. 2.
DICOM: DICOM (Digital Imaging and Communications in Medicine) is an international standard that was developed to improve the quality and communication of digital images in radiology. In short, the DICOM display function results in more visible grayscales in the images. Barco recommends selecting the DICOM display function for most medical viewing applications.
4. Advanced operation 4.12 Ambient Light Compensation (ALC) About ALC Ambient Light Compensation (ALC) can only be enabled on your display when the DI- COM display function is selected. Therefore, please refer to "Display functions", page 21 to correctly set the display function. When ALC is enabled, the DICOM display function will be recalculated taking a preset ambient light cor- rection value into account.
Embedded QA is not a replacement for the Barco MediCal QAWeb solution. Although Embedded QA is a reliable option to perform a simple calibration or compliance test, Barco still highly recommends MediCal QAWeb as the solution of choice for calibration and QA. Medical QAWeb brings many benefits such as centralized asset management, the ability to schedule tasks, remote man-...
4. Advanced operation plays from the moment it is installed and running. MediCal QAWeb Agent will take over from Embedded QA and overwrite any settings which were applied by Embedded QA. 4.15.2 DICOM status report About DICOM status report Following information is available: DICOM Compliance Status (status since last compliance check): •...
4. Advanced operation 4.15.4 DICOM calibration About DICOM calibration The DICOM calibration will add a correction to the current DICOM curve to approach the perfect DICOM curve as well as possible. To start DICOM calibration: 1. Bring up the OSD main menu. 2.
High Dynamic Range (HDR) standard, usually used on color displays. HDR2 HDR2 is a Barco specific mode featuring 10-bit video encoding following the High Dynamic Range (HDR) standard but allowing full refresh rate (which is not always possible with HDR1). This mode is usually used on color displays.
4. Advanced operation Dual 10 (only with Barco display controller) Dual 10 is a Barco specific 10-bit video encoding mode which is usually used on grayscale displays and which allows full refresh rate. Automatic When selecting this option, your Coronis 5MP LED...
4. Advanced operation Refresh Rate Allows to manually select the refresh rate of the image source video input signal depending on the maximum refresh rate of the display controller connected to your display. Color Depth Allows to change the color depth to 8 or to 10 bit. To manually set EDID timings: 1.
4. Advanced operation 4.23 Display status About display status The Status submenu of the OSD menu provides info on the current status of your display (runtimes, tem- peratures, etc.), the status of the connected image sources (video encoding mode, timings, etc.), the current calibration status of your display (display function, luminance, ALC, etc.) and the status about activated connections.
5. Repacking instructions 5. REPACKING INSTRUCTIONS Before repacking the display, follow the instruction to replace the foot pro- ARNING tection buffer to prevent damage to the display. Foot protection buffer To replace the foot protection buffer 1. Place the display on a stable surface. 2.
6. Cleaning your display 6. CLEANING YOUR DISPLAY Cleaning instructions To clean the display Clean the display using a sponge, cleaning cloth or soft tissue, lightly moistened with a recognized clean- ing product for medical equipment. Read and follow all label instructions on the cleaning product. In case of doubt about a certain cleaning product, use plain water.
Page 38
6. Cleaning your display K5902120 CORONIS 5MP LED DISPLAY 18/01/2018...
7. Important information 7. IMPORTANT INFORMATION Safety information General recommendations Read the safety and operating instructions before operating the device. Retain safety and operating instructions for future reference. Adhere to all warnings on the device and in the operating instructions manual. Follow all instructions for operation and use.
Page 40
7. Important information To fully disengage the power to the device, please disconnect the power cord from the AC inlet. High magnetic environment • The device shall not be used in the high magnetic environment of an MRI scanner. • The installer shall assess the magnetic environment before installation or use of the device.
Electronic Products ” (Also called RoHS of Chinese Mainland), the table below lists the names and contents of toxic and/or hazardous substances that Barco’s product may contain. The RoHS of Chinese Mainland is included in the MCV standard of the Ministry of Information Industry of China, in the section “Limit Requirements of toxic substances in Electronic Information Products”.
Regulatory compliance information Indications for use The Coronis 5MP LED Display (MDCG-5221) display is intended to be used in displaying and viewing digital images, for review and analysis by trained medical practitioners. It is designed for radiology and digital mammography applications. Caution (USA): Federal law restricts this device to sale by or on the order of a physician.
The manufacturing country of the product is indicated on the product label (“Made in …”). Importers contact information To find your local importer, contact one of Barco’s regional offices via the contact information provided on our website (www.barco.com). FCC class B This device complies with Part 15 of the FCC Rules.
Page 44
7. Important information Emissions test Electromagnetic environment – Compliance Guidance RF emissions Class B The Coronis 5MP LED Display is suitable for use in all CISPR 11 establishments, including Harmonic emissions Class D domestic establishments and IEC 61000-3-2 those directly connected to the Voltage fluctuations/ flicker Complies public low-voltage power supply...
Page 45
7. Important information Immunity test Electromagnetic IEC 60601 Compliance level environment – Test levels guidance Voltage dips, short Mains power quality < 5% U (> 95% dip in < 5% U (> 95% dip in interruptions and voltage ) for 0.5 cycle ) for 0.5 cycle should by that of a typical variations on power...
Page 46
7. Important information Immunity test Electromagnetic IEC 60601 Compliance level environment – Test levels guidance survey, should be less than the compliance level in each frequency range. Interference may occur in the vicinity of equipment marked with symbol: At 80 MHz and 800 MHz, the higher frequency range applies. These guidelines may not apply in all situations.
7. Important information These guidelines may not apply in all situations. Electromagnetic propagation is af- fected by absorption and reflection form structures, object and people. Explanation of symbols Symbols on the device On the device or power supply, you may find the following symbols (nonrestrictive list): Indicates compliance with Part 15 of the FCC rules (Class A or Class B) Indicates the device is approved according to the UL regulations Indicates the device is approved according to the UL regulations for Canada...
Page 48
7. Important information Indicates the USB connectors on the device Indicates the DisplayPort connectors on the device Indicates the legal manufacturer Indicates the manufacturing date Indicates the temperature limitations for the device to safely operate within specs Indicates the device serial number Indicates the device part number or catalogue number Warning: dangerous voltage Caution...
Barco software products are the property of Barco. They are distributed under copyright by Barco NV or Barco Inc., for use only under the specific terms of a software license agreement between Barco NV or Barco Inc. and the licensee. No other use, duplication, or disclosure of a Barco software product, in any form, is authorized.
Page 51
7. Important information Power rating 24 VDC, 4 A; 5 VDC, 0.5 A Power requirements This device shall only be powered by the following medical approved power supply: Sinpro, type CPU110-201 Ratings marked on the medical power supply: • Input rating: 100–240 VAC, 1.5–0.6 A, 47-63 HZ •...
A list of the Open Source Software components used is available in the applicable EULA, through the “My Barco” section of the Barco website or through other (online) means. Copyright on each Open Source Software component belongs to the respective initial copyright holder, each additional contributor and/or their respective assignee(s), as may be identified in the respective Open...
Page 53
Barco whatsoever. You further acknowledge that any such additions, changes or modifications may impair the ability of Barco – at Barco’s sole discretion - to continue to provide ser- vice, warranties, software updates, fixes, maintenance, access or such similar abilities, without any recourse or claim towards Barco whatsoever.
Need help?
Do you have a question about the MDCG-5221 and is the answer not in the manual?
Questions and answers