Operating Temperature
Optical Interface
Lens Mount
Sensor to Camera Front Distance
Sensor Alignment (aligned to
sides of camera)
Compliance
Regulatory Compliance
Table 4: P4-CC-02K Operating Ranges
Operating Ranges
Dynamic Range
61.8 dB
Random Noise
3.36 DN** rms
Responsivity
Refer to graph
Gain
1x to 10x Nominal Range (not including individual RGB gains for white balance)
DC Offset
< 11 DN
PRNU
< 2% @50% Sat
FPN
< 6.3 DN
SEE
3.96 nJ / cm2
NEE
3.2 pJ / cm2
Antiblooming
> 100 x Saturation
Integral non-
< 2% DN
linearity
Teledyne DALSA
P4-CC-02K04T-00-R
P4-CC-02K07T-00-R
P4-CC-02K07Q-00-R
P4-CC-04K04T-00-R
P4-CC-04K07T-00-R
P4-CC-02K04T-01-R
P4-CC-04K04T-01-R
0 °C to 65 °C, front plate temperature
Camera Models
P4-CC-02K04T-00-R
P4-CC-02K07T-00-R
P4-CC-02K07Q-00-R
P4-CC-04K04T-00-R
P4-CC-04K07T-00-R
P4-CC-02K04T-01-R
P4-CC-04K04T-01-R
CE and RoHS, GenICam
Red
Green
61.8 dB
3.36 DN rms
< 11 DN
< 2% @50% Sat
< 6.3 DN
4.39nJ / cm2
3.6 pJ / cm2
62 mm (W) x 62 mm (H) x 48 mm (D)
< 340 g (without heat sinks)
62 mm (W) x 62 mm (H) x 37 mm (D)
< 300 g (without heat sinks)
M58 x 0.75
F-mount adapter available
12 mm
Flatness
y (parallelism)
x
y
z
z
Flatness
y (parallelism)
x
y
z
z
Performance
Blue
61.8 dB
3.36 DN rms
< 11 DN
< 2% @50% Sat
< 6.3 DN
6.80 nJ / cm2
5.6 pJ / cm2
9
Value
50 µm
0.08° or 81 µm
± 100 µm
± 100 µm
± 250 µm
± 0.2°
50 µm
0.08° or 81 µm
± 300 µm
± 300 µm
± 300 µm
± 0.3°
Mono
61.8 dB
3.36 DN rms
< 11 DN
< 2% @50% Sat
< 6.3 DN
3.64 nJ / cm2
3.0 pJ / cm2
03-032-20180-06