Table 10- 5
Parameters for the MC_Power instruction
Parameter and type
Axis
IN
Enable
IN
StopMode
IN
Status
OUT
Busy
OUT
Error
OUT
ErrorID
OUT
ErrorInfo
OUT
Easy Book
Manual, 11/2011, A5E02486774-04
Data type
Description
TO_Axis_1
Axis technology object
Bool
FALSE (default): All active tasks are aborted according to the
parameterized "StopMode" and the axis is stopped.
TRUE: Motion Control attempts to enable the axis.
Int
0: Emergency stop - If a request to disable the axis is pending, the
axis brakes at the configured emergency deceleration. The axis is
disabled after reaching standstill.
1: Immediate stop - If a request to disable the axis is pending, this
axis is disabled without deceleration. Pulse output is stopped
immediately.
Bool
Status of axis enable:
FALSE: The axis is disabled.
TRUE: The axis is enabled.
Bool
False: MC_Power is not active.
TRUE: MC Power is active.
Bool
FALSE: No error
TRUE: An error has occurred in motion control instruction "MC_Power"
or in the associated technology object. The cause of the error can be
found in parameters "ErrorID" and "ErrorInfo".
Word
Error ID for parameter "Error""
Word
Error info ID for parameter "ErrorID"
The axis does not execute motion control tasks and does not
accept any new tasks (exception: MC_Reset task).
The axis is not homed.
Upon disabling, the status does not change to FALSE until the
axis reaches a standstill.
The axis is ready to execute motion control tasks.
Upon axis enabling, the status does not change to TRUE until
the signal "Drive ready" is pending. If the "Drive ready" drive
interface was not configured in the axis configuration, the status
changes to TRUE immediately.