As a System

As a system, the DPS300 is made up of:
DPS300
mounting
plate
customer
conduit
Optional Siemens
Skimmer Guard
The Skimmer Guard
protects the transducer by
allowing it to ride over a
passing skimmer.
DPS300 System Integration
Assemble the transducer to the Siemens Skimmer Guard if provided. Otherwise
install directly to your conduit with a ¾" to 1" NPT or BSP reducer.
Refer to the Skimmer Guard section for dimension and assembly details. Refer to
the XCT-12 manual for connection and wiring details only.
Assemble the Siemens Mounting Assembly, if provided, to the handrail. And,
mount the transducer (with Skimmer Guard if provided) to the Mounting Assembly.
Otherwise mount the transducer assembly in a secure fashion.
Refer to the Mounting Assembly section for dimensions and assembly details.
Install the DPS300 and program the unit for your specific application.
Refer to the Application and Parameters sections of this manual.
7ML19981BC01
minimum
one DPS300
one XCT-12 transducer
Siemens XCT-12
The ultrasonic transducer used with the DPS300. If
the DPS300 is programmed to monitor two clarifiers,
then two transducers are required.
Note:
Operation of the transducer requires that the face be
immersed 3 to 6 cm into the clarifier wastewater.
15
maximum
one DPS300
two XCT-12 transducers
one Skimmer Guard per transducer
one Mounting Assembly per transducer
one SmartLinx communications module
Siemens Mounting Assembly
Mounts the transducer to
handrails along the clarifier
walkway or bridge.
InterRanger DPS300