Checking The Beam Coupling: Axialscan (Standard), Axialscan (Motorized), Focusshifter (Standard); Preparation - RAYLASE AXIALSCAN Manual

3-axis subsystems for laser beam deflection
Table of Contents

Advertisement

Chapter 5
5.4
5.4.1
In order to be able to check the beam coupling, all components located in the beam path must
be removed and the deflection unit dismantled. The process for doing this is as follows:
Fig. 16
Preparing the
beam coupling
AXIALSCAN
(standard)
AXIALSCAN
(motorized)
FOCUSSHIFTER
(standard)
o Remove the following components in turn:
-
-
o Mark the installation position of the focusing lens (2) or the two focusing lenses for re-
installation.
o Remove the following components in turn:
-
-
-
o Protect the focusing lens, deflection unit and linear translator against dust.
38
RAYLASE 3-Axis Subsystems for Laser Beam Deflection
Checking the beam coupling: AXIALSCAN (Standard),
AXIALSCAN (motorized), FOCUSSHIFTER (Standard)

Preparation

Connecting cable between linear translator module and deflection unit
Linear translator module cover (1).
Focusing lens and second focusing lens if fitted.
Deflection unit (4); in subsystems with spacer: Only dismantle the deflection unit, not
the spacer (3) and the mounting plate for the deflection unit.
Linear translator, (5) or (6) depending on model.
Installation
MN025 / v2.1.0