English
CAUTION! Risk of injury and damage to property!
Non-approved fluids can damage the pump and also cause injury.
Comply strictly with the relevant safety data sheets and manufacturer's data!
2)
Observe the specifications of the manufacturer regarding the mixing ratios.
2)
Additives are to be mixed to the fluid on the pressure side of the pump, even if this
is contrary to the recommendations of the additive manufacturer!
CAUTION! Risk of property damage!
When changing, refilling or replenishing the fluid with additives, there is a risk of mate-
rial damage caused by enrichment of chemical substances. The pump is to be flushed
separately for a sufficient amount of time to ensure the old fluid has been completely
removed from the interior of the pump.
For alternating pressure flushing, the pump must be detached. Chemical flushing is not
suitable for the pump; in this case, the pump must be removed from the system for the
duration of cleaning.
Minimum inlet pressure (above atmospheric pressure) at the pump suction port in order to
avoid cavitation noises (at fluid temperature T
Nominal diameter
Rp 1
Rp 1¼
The values apply up to 300 m above sea level; addition for higher locations:
0.01 bar/100 m increase in height.
5.3
Scope of delivery
Pump assembly
• 2 gaskets
• Control cable (1.5 m) for SSM and 0-10V connection connected to pump at the factory.
• Wilo-Connector included
• Two-piece thermal insulation shell
• Material:
• Thermal conductivity:
• Flammability:
• Installation and operating instructions
5.4
Accessories
Accessories must be ordered separately:
See catalogue for a detailed description.

6 Description and function

6.1
Description of the pump
The pump consists of a hydraulic system, a glandless pump motor with a permanent mag-
net rotor, and an electronic control module with an integrated frequency converter. The
control module contains a red operating knob (Fig. 1, item 4) that can be used to set the
pump's differential pressure to an adjustable value between 1 and 5 m. The pump housing
is clad with an insulating shell for thermal insulation.
26
T
Med
-10°C...+50°C
0.05 bar
0.05 bar
EPP, polypropylene foam
0.04 W/m as per DIN 52612
B2 class as per DIN 4102, FMVSS 302
):
Med
T
Med
+95°C
0.45 bar
0.45 bar
T
Med
+110°C
1.1 bar
1.1 bar
WILO SE 05/2017