Bosch FPA-5000 Product Information page 37

Modular fire panel
Hide thumbs Also See for FPA-5000:
Table of Contents

Advertisement

Modular Fire Panel
Connection
labeling
24 V + / -
24 V + / -
Lower connections, from left to right
MAIN + / -
MAIN FAULT Signal input for power supply unit fault
BAT1 + / -
BAT2 + / -
FAULT AC -
FAULT BAT - Switch output for battery fault
FAULT Σ -
FAULT +24V Switch output +
Technical specifications
Input voltage
Current consumption at 24 V DC
Permissible battery capacities
Maximum current
Fault threshold
Outputs
2 switch outputs
1 switch output
1 switch output
1 switch output
Display and operating elements
1 green LED
3 yellow LEDs
1 button
Permissible storage temperature
Dimensions (H x W x D)
Weight
Bosch Sicherheitssysteme GmbH
Top connection,
from left to right
Switch output +24 V max. 2.8 A (battery buffered, optional)
Switch output +24 V max. 2.8 A (battery buffered, optional)
Power supply unit connection
Battery pair 1 connection
Battery pair 2 connection
Switch output for mains fault
Switch output for collective fault
Standby operation
Fault
with 2 batteries
with 4 batteries
of the module
to panel rails
of the switch outputs
+24 V / 0 to 2.8 A, battery buffered
Battery fault, 0 V / 0 to 20 mA
Mains fault, 0 V / 0 to 20 mA
Collective fault in accordance with EN 54-4, 0 V / 0 to 20 mA
Mains power on
Mains fault, batt. fault 1, batt. fault 2
Charging batteries, testing LEDs, resetting faults
Product Information
20.4 V to 30 V
25 mA
40 mA
24-26 Ah, 36-45 Ah
48-52 Ah, 72-90 Ah
Max. 6 A
Max. 6 A
Max. 5.6 A (2 x 2.8 A cannot be connected in
parallel)
Max. 430 milliohms battery resistance
-25 °C to 85 °C
Approx. 127 x 96 x 60 mm (5.0 x 3.8 x 2.4 inches)
193 g
Product Description | en