Minimum Permissible Bending Radius Of The Combination Cable; Current-Carrying Capacity Of The Cables - Siemens SIMOTICS-T 1FW68 Engineering Manual

Segment motors, radial for sinamics s120
Table of Contents

Advertisement

Electrical connection
8.3 System integration
8.3.4

Minimum permissible bending radius of the combination cable

Refer to the following table for the minimum permissible bending radii for combination cables
that are either fixed or moved.
Table 8- 4
Minimum permissible bending radii for combination cables for stator segments up to 66 A
Article No.
Number of conduc-
tors x cross section
in mm
6FX7002-5EA31-....
(4 x 2.5) + (4 x 0.5)
6FX7002-5EA41-....
(4 x 4) + (4 x 0.5)
6FX7002-5EA51-....
(4 x 6) + (4 x 0.5)
6FX7002-5EA61-....
(4 x 10) + (4 x 0.5)
6FX7002-5EA71-....
(4 x 16) + (4 x 0.5)
8.3.5

Current-carrying capacity of the cables

To electrically connect stator segments with a current demand of up to 66 A, combination
cables with a cross-section of up to 16 mm
for the power and four conductors for the signals. The cross-section for each of the signal
conductors is 0.5 mm
You must use single conductor cables for higher current demands. You require a total of
three power cables for each stator segment. An additional cable/conductor is required for the
protective conductor connection. Further, you require an additional signal cable.
The cross-section of the power cable conductors is based on the rated current of the stator
segment. The rated current of the stator segment must be less than the current-carrying
capacity of the cable according to DIN EN 60204-1 (routing type C). The table below
specifies the maximum permissible rated current of the stator segment for different cross-
sections of the power cable conductors.
140
Maximum diame-
ter of the combi-
nation cable
2
in mm
13.8
15.2
17.3
22.8
23.8
.
2
Dynamic bending
Static bending
radius in mm
radius in mm
110
120
130
165
185
are used. The cables must have four conductors
2
Configuration Manual, 04/2017, 6SN1197-0AE02-0BP1
Maximum
permissible
rated current in A
60
21
65
28
71
36
92
50
98
66
1FW68 radial segment motors