2.3.5
Ambient conditions for stationary use
Based on DIN EN 60721-3-3 (for stationary use at weather-protected locations)
Table 2- 2
Climatic ambient conditions
Lower air temperature limit:
Upper air temperature limit:
Lower relative humidity limit:
Upper relative humidity limit:
Rate of temperature fluctuations:
Condensation:
Formation of ice:
Stationary use:
Devices can only be operated in locations that are fully protected against the weather (in halls or rooms).
Table 2- 3
Biological ambient conditions
Stationary use:
Table 2- 4
Mechanically active ambient conditions
Stationary use:
Table 2- 5
Mechanical ambient conditions
Stationary use:
2.3.6
Scope of delivery
2.3.6.1
Segment motors
Segment motors are only available in the form of individual components:
● Stator segments
● Rotor segments
● Connecting cables
T-sliding blocks to fix rotor and stator segments are not available.
1FW68 radial segment motors
Configuration Manual, 04/2017, 6SN1197-0AE02-0BP1
- 5 °C (deviates from 3K3)
+ 40 °C
5 %
85 %
Max. 0.5 K/min
Not permissible
Not permissible
Class 3K3
Class 3B1
Class 3S1
Class 3M3
Description of the motors
2.3 Technical features and ambient conditions