Set horizontal tab stops
IModel
ASCII
I
Decimal
I
Hexadecimal
I
I Both I <ESC> "D" ,,f
172 .
<0>
I 27 68 rz/ ,,2... 0 I
IB 44 rz/ ,,2 ..00 I
Cancels all current horizontal tab stops and sets new tab stops at
columns nl, n2, etc. in the current character pitch (pica pitch if
proportional spacing is currently selected), where nl, n2,
etc. are
numbers between 1 and 255. The maximum number of horizontal
tab stops allowed is 32 in Standard mode and 28 in IBM mode. The
tab stops must be specified in ascending order; any violation of
ascending order terminates the tab stop list. Standard termination is
by the <0> control code. To clear all tab stops, specify <ESC> "D"
<o>.
Reset all tab stops
Mode
ASCII
Decimal
Hexadecimal
IBM
<ESC> "R"
27 82
IB 52
Resets the horizontal tab stops to their power-up values according to
which a tab stop is set every 8 colulmnsstarting at column 9. Also
clears all vertical tab stops.
Horizontal tab
Mode
ASCII
Decimal
Hexadecimal
Both
<HT>
9
09
Moves the print position to the next horizontal tab stop. Ignored if
there is no next horizontal tab stop in the current line. Note that when
underlining is selected, spaces skipped by horizontal tabulation are
not underlined.