The following steps allow for proper bar sizing measurements:
Step 1: Press ESC to exit the Locate Cover screen.
Step 2: In the Main menu screen use the up or down arrow keys to
navigate the highlight to the Locate category.
Figure 17: Bar Size Function
Step 3: Press the right arrow key on the front panel to choose
Locate: Size and press Enter.
Step 4: In the BAR SIZE screen, use the sensor probe to locate the
center of the rebar either by using the bar display or the numerical
output value in brackets [ ].
Figure 18: Bar Size Screen