8. Select the measurement and its associated output option.
9. Click Finish and save the program. Send the program just created to the GRANITE data
logger if it is connected to the computer.
10. If the thermocouple is connected to the VOLT 100 series, check the output of the
thermocouple in the data logger support software data display in LoggerNet or RTDAQ to
make sure it is making reasonable measurements.

7. Overview

The VOLT 100 series expands the number of analog measurement channels and increases the
measurement-speed potential in a data logger system. GRANITE Measurement Modules operate
through a data logger program and communicate using the CAN peripheral interface (CPI). A
single data logger can operate up to 50 GRANITE Measurement Modules.
The VOLT 100 series is compatible with the following data loggers:
GRANITE 10
l
GRANITE 9
l
GRANITE 6
l
CR6
l
CR1000X
l
VOLT 100 series