PLUS+1 SC0XX-1XX Controller Family
Product installation and start-up
24 |
©
Danfoss | June 2016
13. It is better to use wire harness anchors that will allow wires to float with respect to the machine rather
than rigid anchors.
14. Electronic modules should be grounded to a dedicated conductor of sufficient size that is connected
to the battery (-).

Electronic components welding guidelines

Remove electronic components from the machine before any arc welding. The following is
recommended when welding on a machine equipped with electronic components:
Turn the engine off.
Disconnect the negative battery cable from the battery.
Do not use electronic components to ground the welder.
Clamp the ground cable for the welder to the component that will be welded as close as possible to
the weld.
PLUS+1
USB/CAN Gateway
®
Communication (software uploads and downloads and service and diagnostic tool interaction) between
PLUS+1
®
modules and a personal computer (PC) is accomplished using the vehicle's PLUS+1
network.
The PLUS+1
®
CG150-2 USB/CAN gateway provides the communication interface between a PC USB port
and the vehicle CAN bus. When connected to a PC, the gateway acts as a USB slave. In this configuration,
all required electrical power is supplied by the upstream PC host. No other power source is required.
Refer to the PLUS+1
®
GUIDE Software User Manual, literature number 10100824, for gateway set-up
information. Refer to the CG150-2 USB/CAN Gateway Data Sheet, literature number L1412468, for
electrical specifications and connector pin details.
®
CAN
L1415500 | BC00000235en-US0201