Danfoss PLUS+1 SC0XX-1 Series Technical Information

Danfoss PLUS+1 SC0XX-1 Series Technical Information

Sc controllers

Advertisement

Technical Information
PLUS+1 SC Controllers
SC0XX-1XX Controller Family
powersolutions.danfoss.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PLUS+1 SC0XX-1 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Danfoss PLUS+1 SC0XX-1 Series

  • Page 1 Technical Information PLUS+1 SC Controllers SC0XX-1XX Controller Family powersolutions.danfoss.com...
  • Page 2 Revision history Table of revisions Date Changed June 2016 Updated Digital/Analog/Resistance/4-20 mA Current (DIN/AIN/ResIN/CrntIN) Specifications 0201 March 2015 Various text update and added tables for control of outputs December 2014 First edition L1415500 | BC00000235en-US0201 © Danfoss | June 2016...
  • Page 3: Table Of Contents

    Mating connectors................................... 22 Product installation..................................22 Mounting..................................... 22 Machine diagnostic connector............................23 Grounding....................................23 Hot plugging....................................23 Recommended machine wiring guidelines........................23 Electronic components welding guidelines........................24 ® PLUS+1 USB/CAN Gateway..............................24 L1415500 | BC00000235en-US0201 | 3 © Danfoss | June 2016...
  • Page 4: Technical Information (Ti)

    ® hardware modules • How to upload and download tuning parameters • How to use the PLUS+1 ® Service Tool Latest version of technical literature Danfoss product literature is online at: http://powersolutions.danfoss.com/literature/ L1415500 | BC00000235en-US0201 © Danfoss | June 2016...
  • Page 5: User Liability And Safety Statements

    User liability and safety statements OEM responsibility The OEM of a machine or vehicle in which Danfoss products are installed has the full responsibility for all consequences that might occur. Danfoss has no responsibility for any consequences, direct or indirect, caused by failures or malfunctions.
  • Page 6: Overview

    CAN system, with intelligence in every node, or as stand-alone control for smaller machine systems. PLUS+1 ® systems are incrementally expandable: additional modules can be easily added to the machine CAN bus to increase system capabilities or computational power. L1415500 | BC00000235en-US0201 © Danfoss | June 2016...
  • Page 7: Inputs/Outputs Types And Specifications

    Pins that support multiple input or output types are user-configurable using PLUS+1 ® GUIDE software. Refer to product data sheets for the input/output (I/O) content of individual modules. L1415500 | BC00000235en-US0201 | 7 © Danfoss | June 2016...
  • Page 8: Inputs

    Input impedance (pulled up to 5 Vdc or ground, high range) kΩ 13.0 13.4 — — Input impedance (pulled up to 2.5 Vdc high range) kΩ — — Input impedance (no pull ups, high range) kΩ — — L1415500 | BC00000235en-US0201 © Danfoss | June 2016...
  • Page 9: Digital/Analog/Frequency (Din/Ain/Freqin)

    Worst case error (middle range) — — Precision (low range) — — Worst case error (low range) — — Input impedance (pulled to 5 Vdc or ground, low range) kΩ 13.9 14.3 L1415500 | BC00000235en-US0201 | 9 © Danfoss | June 2016...
  • Page 10: Digital/Analog/Resistance/4-20 Ma Current (Din/Ain/Resin/Crntin)

    AD counts and load resistance in ohms. Rheostat inputs chart 30000 25000 20000 15000 10000 5000 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Load Resistance (Ω) P200 083 L1415500 | BC00000235en-US0201 10 | © Danfoss | June 2016...
  • Page 11 Input impedance (pulled to 5 Vdc or ground middle range) KΩ 13.9 14.3 Input impedance (pulled to 2.5 Vdc middle range) KΩ Input impedance (no pull ups middle range) KΩ L1415500 | BC00000235en-US0201 | 11 © Danfoss | June 2016...
  • Page 12: Outputs

    Shut off Processor control with hardware WatchDog override. L1415500 | BC00000235en-US0201 12 | © Danfoss | June 2016...
  • Page 13: Control Of Dout

    0 or False (if configured as a digital output). Refer to individual module data sheets for the maximum allowable output current for each PLUS+1 module. L1415500 | BC00000235en-US0201 | 13 © Danfoss | June 2016...
  • Page 14 250 ms before the secondary controller's application is allowed to re-enable the redundant switch. When the switch controlled by the secondary controller is enabled then the PWM outputs are L1415500 | BC00000235en-US0201 14 | © Danfoss | June 2016...
  • Page 15: Control Of Pwmout/Dout

    LED shared with the red LED light pipe will be controlled by the secondary controller. When either yellow LED is enabled the signal will override its shared green or red LED. L1415500 | BC00000235en-US0201 | 15 © Danfoss | June 2016...
  • Page 16: Controller Area Network Specifications

    The table below can be used to estimate system CAN bus loading and the memory impact of I/O modules on their associated controller. L1415500 | BC00000235en-US0201 16 | © Danfoss | June 2016...
  • Page 17: Internal Processor-To-Processor Uart

    Has the ability to disable sourcing (disconnect high-side switch) of each output individually in the event that any of these signals indicates there is a fault condition as defined by the application. L1415500 | BC00000235en-US0201 | 17 © Danfoss | June 2016...
  • Page 18: Product Ratings

    SC024-110/112: C1p5, C1p6, C1p7, C1p10, C1p11, C1p12, C2p1, C2p7, C2p8 ‒ SC024-120/122: C1p5, C1p6, C1p7 ‒ SC050-120/122: C1p5, C1p6, C1p7, C1p19, C1p20, C1p23, C1p24, C1p31, C1p32 ‒ SC050-13H: C1p5, C1p6, C1p7, C1p19, C1p20, C1p23, C1p24, C1p31, C1p32 L1415500 | BC00000235en-US0201 18 | © Danfoss | June 2016...
  • Page 19: Sensor Power Supply Ratings

    Nominal 3.3 EEPROM Write/Erase ratings To prevent unexpected memory writes, care must be taken to ensure memory with a high number of read/write cycles is either U32 or S32 data types. L1415500 | BC00000235en-US0201 | 19 © Danfoss | June 2016...
  • Page 20: Environmental Testing Criteria

    IEC 60068-2-1, test Ab, IEC 60068-2-2 test Bd Thermal cycle IEC 60068-2-2, test Na, IEC 60068-2-38 (partial) Humidity IEC 60068-2-78, IEC 60068-2-30 test Damp heat steady state and cyclic. Degree of protection IEC 60529 L1415500 | BC00000235en-US0201 20 | © Danfoss | June 2016...
  • Page 21: Modules Housing

    Once assembled at the factory, the housing cannot be opened for service. Opening the modules housing will void the factory warranty. L1415500 | BC00000235en-US0201 | 21 © Danfoss | June 2016...
  • Page 22: Product Installation And Start-Up

    The SC Controller Family use Deutsch ® connectors. Danfoss has assembled a mating connector kit, referred to as a bag assembly, for the 24 and 50 pin module housings. Mating connector bag assembly ordering information is found in the product data sheet for each module.
  • Page 23: Machine Diagnostic Connector

    11. All analog sensors should be powered by the sensor power source from the PLUS+1 controller and ® ground returned to the sensor ground pin on the PLUS+1 controller. ® 12. Sensor lines should be twisted about one turn every 10 cm [4 in]. L1415500 | BC00000235en-US0201 | 23 © Danfoss | June 2016...
  • Page 24: Electronic Components Welding Guidelines

    ® GUIDE Software User Manual, literature number 10100824, for gateway set-up information. Refer to the CG150-2 USB/CAN Gateway Data Sheet, literature number L1412468, for electrical specifications and connector pin details. L1415500 | BC00000235en-US0201 24 | © Danfoss | June 2016...
  • Page 25 Technical Information PLUS+1 SC0XX-1XX Controller Family L1415500 | BC00000235en-US0201 | 25 © Danfoss | June 2016...
  • Page 26 Technical Information PLUS+1 SC0XX-1XX Controller Family L1415500 | BC00000235en-US0201 26 | © Danfoss | June 2016...
  • Page 27 Technical Information PLUS+1 SC0XX-1XX Controller Family L1415500 | BC00000235en-US0201 | 27 © Danfoss | June 2016...
  • Page 28 Phone: +86 21 3418 5200 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed.

Table of Contents