Inputs; Input Types; Digital/Analog (Din/Ain), A/D Refresh Rates - Danfoss PLUS+1 SC0XX-1 Series Technical Information

Sc controllers
Table of Contents

Advertisement

Technical Information
PLUS+1 SC0XX-1XX Controller Family

Inputs

Input types

Digital/Analog (DIN/AIN), A/D Refresh Rates

General
Description
Response to input below minimum voltage
Response to input above maximum voltage
Response to input open
Voltage working ranges
Specifications
Description
Allowed voltage at pin
Maximum discernable voltage (high range)
Minimum discernable voltage (high range)
Maximum discernable voltage (middle range
Minimum discernable voltage (low range)
Precision (high range)
Worst case error (high range)
Precision (middle range)
Worst case error (middle range)
Input impedance (pulled up to 5 Vdc or ground, middle range)
Input impedance (pulled up to 2.5 Vdc middle range)
Input impedance (no pull ups, middle range)
Input impedance (pulled up to 5 Vdc or ground, high range)
Input impedance (pulled up to 2.5 Vdc high range)
Input impedance (no pull ups, high range)
8 |
©
Danfoss | June 2016
Digital or Analog (DIN/AIN)
Analog Input Offset
A/D Refresh Rate
Digital/Analog/Frequency (DIN/AIN/FreqIN)
Digital/Analog/Resistance/4-20 mA Current (DIN/AIN/ResIN/CrntIN)
Digital/Analog/1.6 Vdc Sensor Power (DIN/AIN/SnsrPwr1.6Vdc)
Digital/Analog/3.6 Vdc Sensor Power (DIN/AIN/SnsrPwr3.6Vdc)
Each PLUS+1
®
module input pin supports one of the above functional types. For pins with multiple
functions, input configurations are user programmable using PLUS+1
Multifunction pins that are configured to be DIN are subject to the same update rates as the analog input
function for that pin. Debounce is not used, as hysteresis is built into the function. The time to recognize
a transition is dependent on the timing of the switch activation and the sample rate.
Comment
Non-damaging, non-latching; reading saturates to the low limit.
Non-damaging, non-latching; reading saturates to the high limit.
Pin configuration dependent: No pull up/ no pull down = floating
Pull up to 5 Vdc = 5 Vdc
Pull down = 0 Vdc
Pull up/ pull down = 2.5 Vdc
Programmable (see specific data sheets for ranges).
Units
Minimum
Maximum
Vdc
0
36
Vdc
34.10
36.5
mV
0
130
Vdc
5.13
5.38
mV
0
20
mV
— —
9
Vdc
— —
1.16
mV
— —
1.3
mV
— —
120
kΩ
13.9
14.3
kΩ
7.2
7.4
kΩ
230
236
kΩ
13.0
13.4
kΩ
6.9
7.1
kΩ
108
112
®
GUIDE templates.
Comment
— —
35.3 Vdc is typical.
— —
5.26 Vdc is typical.
— —
— —
— —
— —
— —
— —
— —
— —
— —
— —
— —
L1415500 | BC00000235en-US0201

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents