Handling; Assembly Information; Mounting Conditions - Viega Multiplex Trio F Instructions For Use Manual

Drain/overflow functional unit
Hide thumbs Also See for Multiplex Trio F:
Table of Contents

Advertisement

3 Handling

3.1

Assembly information

3.1.1

Mounting conditions

Pipe interrupter
Multiplex Trio F drain/overflow functional unit
The following requirements exist for the mounting of the drain / over-
flow:
The bathtub is installed.
n
n
The drainage line is installed all the way to the bathtub.
The underside of the bathtub is accessible.
n
Backflow situation: If a negative pressure situation should occur when
the bathtub is filled, there is a possibility that bath water may flow back
into the drinking water system.
To ensure that no bath water flows back into the drinking water system,
a pipe interrupter must be installed in the pipeline between the shut-off
fitting and the bathtub inlet.
The following schematic diagram shows what this should look like:
Handling
9 from 25

Advertisement

Table of Contents
loading