Viega Multiplex Trio E Instructions For Use Manual

Viega Multiplex Trio E Instructions For Use Manual

Fitting, electronic mixing unit for filling a bathtub
Hide thumbs Also See for Multiplex Trio E:

Advertisement

Quick Links

Multiplex Trio E fitting, electronic mixing
unit
Instructions for Use
for filling a bathtub (electronically controlled), in connection with
Multiplex Trio, Multiplex Trio F, Rotaplex Trio or Rotaplex Trio F
(optional electric driven)
Model
6146
en_INT
Year built:
from 01/2010

Advertisement

Table of Contents
loading

Summary of Contents for Viega Multiplex Trio E

  • Page 1 Multiplex Trio E fitting, electronic mixing unit Instructions for Use for filling a bathtub (electronically controlled), in connection with Multiplex Trio, Multiplex Trio F, Rotaplex Trio or Rotaplex Trio F (optional electric driven) Model Year built: 6146 from 01/2010 en_INT...
  • Page 2 Multiplex Trio E fitting, electronic mixing unit 2 from 38...
  • Page 3: Table Of Contents

    Disabling the temperature safeguard 3.3.4 Changing the water inlet 3.3.5 Using personal settings 3.3.6 Electronic operation of the drain 3.3.7 Using the function lock 3.3.8 Cleaning functions 3.3.9 System diagnosis and statistics Troubleshooting Multiplex Trio E fitting, electronic mixing unit 3 from 38...
  • Page 4 Table of contents Care and maintenance 3.5.1 Care tips 3.5.2 Maintenance 3.5.3 Changing the filters in the corner valves 3.5.4 Changing the battery Disposal Multiplex Trio E fitting, electronic mixing unit 4 from 38...
  • Page 5: About These Instructions For Use

    This restriction does not extend to possible operating instructions. The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
  • Page 6: About This Translated Version

    German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation. Multiplex Trio E fitting, electronic mixing unit 6 from 38...
  • Page 7: Product Information

    EN 274 Regulations from section: Maintenance Scope / Notice Regulations applicable in Ger‐ many Thermal disinfection after 72 VDI 6023 hours of non-use Thermal disinfection after 7 days EN 806-5 Multiplex Trio E fitting, electronic mixing unit 7 from 38...
  • Page 8: Safety Advice

    Before opening the control casing, switch off the mains voltage and take steps to prevent accidental re-activation. Lay the cable in the control casing in such a way that it touches nothing. Multiplex Trio E fitting, electronic mixing unit 8 from 38...
  • Page 9: Intended Use

    Maintenance Regular maintenance is part of running the system properly Ä Chapter 3.5.2 „Maintenance“ on page 35. Inform the building owner, the operator or end customer of the maintenance obligations. Multiplex Trio E fitting, electronic mixing unit 9 from 38...
  • Page 10: Product Description

    13 - connection cable with plug connector (extendable as an option) 2.4.2 Technical data Operating pressure maximum 1 MPa (10 bar) Recommended flow pressure 0.1–0.5 MPa (1–5 bar) Pressure difference between maximum 0.1 MPa (1 bar) PWC and PWH Multiplex Trio E fitting, electronic mixing unit 10 from 38...
  • Page 11 Fig. 2: Rate of flow without accessories (corner valves, filling hose, pipe interrupter) 1 - l / min 2 - Δp/bar Fig. 3: Rate of flow with accessories (corner valves, filling hose, pipe interrupter) Multiplex Trio E fitting, electronic mixing unit 11 from 38...
  • Page 12: Functions

    Basic functions The electronic mixing fitting has been optimised for the control of elec‐ trically operated Viega bathtub drains and overflows. When a manually operated drain and overflow is used, all functions of the mixing fitting can be used with the exception of the electronic opening and closing of the drain.
  • Page 13: Control Elements And Menus

    Each colour signifies a different function (see table below). Colour of Function the illumi‐ nated ring Green Standby mode Light blue Changing between bathtub inlet and hand shower Multiplex Trio E fitting, electronic mixing unit 13 from 38...
  • Page 14 Example: Operating status „OFF“ Action Briefly press the control element once. Result The water starts to flow. (Automatic stop after max. 45 minutes.) Multiplex Trio E fitting, electronic mixing unit 14 from 38...
  • Page 15: Accessories

    A water inlet and a drain/overflow for the tub are required to be able to install the product completely. The following four Viega models are optimised for use with an electronic mixing fitting: Multiplex Trio drain / overflow, model 6175.1 Rotaplex Trio drain/overflow, model 6175.2...
  • Page 16 It contains a concealed socket, an empty pipe for the connection cable and a fixing set with sealing collar and chrome-plated cover rosette. Extension cable 3 m extension cable for the control element: model 6146.22. Multiplex Trio E fitting, electronic mixing unit 16 from 38...
  • Page 17: Handling

    The following requirements exist for the mounting of the drain / over‐ flow: The bathtub is installed. The drainage line is installed all the way to the bathtub. The underside of the bathtub is accessible. Multiplex Trio E fitting, electronic mixing unit 17 from 38...
  • Page 18 Observe the local standards and regulations. The pipe interrupter is not included in the scope of delivery and must be ordered separately. Observe the instructions for use of the pipe inter‐ rupter. Multiplex Trio E fitting, electronic mixing unit 18 from 38...
  • Page 19: Installation Dimensions

    The mounting site is such that the planned installation site of the control elements can be reached with a cable of 3 m length (6 m with extension). Multiplex Trio E fitting, electronic mixing unit 19 from 38...
  • Page 20 INFO! When screwing the hoses to the connections, always apply the pipe wrench at the bottom end of the inputs and outputs of the mixing unit. Applying the wrench at the top end may damage the mixing unit. Multiplex Trio E fitting, electronic mixing unit 20 from 38...
  • Page 21 Mount the corner valves to the hot and cold water installations. Unscrew the filter in anti-clockwise direction. Remove the filter. Open the water inlet for a few seconds to flush the pipe. Multiplex Trio E fitting, electronic mixing unit 21 from 38...
  • Page 22 Screw the hoses to the outputs of the mixing unit for bathtub and hand shower. Connect the battery to the control electronics. Make sure that it is properly aligned. Push the battery in until you feel the plug snap into place. Multiplex Trio E fitting, electronic mixing unit 22 from 38...
  • Page 23: Mounting The Control Element

    Behind the drill hole, there is a clearance of at least 40 mm. Guide the connection cable of the control element through the drill hole. Insert the control element in the drill hole. Multiplex Trio E fitting, electronic mixing unit 23 from 38...
  • Page 24 The plug has a groove left and right on one long side which must face forward when plugging in. Set the casing lid on the mixing unit and screw it down. Multiplex Trio E fitting, electronic mixing unit 24 from 38...
  • Page 25: Connecting The Electrical Drain (Optional)

    The electronic mixing fitting has three memory spaces to which the users can save their individual settings. The individual settings include the water temperature, the strength of the water stream and the water volume defined via the inflow time. Multiplex Trio E fitting, electronic mixing unit 25 from 38...
  • Page 26: Setting The Water Inlet

    The fitting has a temperature safeguard at 38 °C to exclude scalding. For information on how to bypass the temperature safeguard, see Ä Chapter 3.3.3 „Disabling the temperature safeguard“ on page 27. Multiplex Trio E fitting, electronic mixing unit 26 from 38...
  • Page 27: Disabling The Temperature Safeguard

    – Children must always be supervised in the bathtub so that they cannot accidentally disable the temperature safeguard. Multiplex Trio E fitting, electronic mixing unit 27 from 38...
  • Page 28: Changing The Water Inlet

    2, or briefly press 3 x z to call up program memory space Result The water flows in according to the saved set‐ tings. Saving personal settings Multiplex Trio E fitting, electronic mixing unit 28 from 38...
  • Page 29 „Factory settings“ on page 25). The water inlet stops. Returning all settings to factory settings Use this function to reset all settings to delivery state (see Ä Chapter 3.3.1 „Factory settings“ on page 25). Multiplex Trio E fitting, electronic mixing unit 29 from 38...
  • Page 30: Electronic Operation Of The Drain

    Keep the control element pressed until the illuminated ring emits turquoise light. Release the control element. Result Confirmation with single flash – functions are available Confirmation with double flash – functions are locked Multiplex Trio E fitting, electronic mixing unit 30 from 38...
  • Page 31: Cleaning Functions

    System diagnosis and statistics Using the diagnosis mode The fitting can carry out an automatic system diagnosis. In this process, the temperature sensor and the volume flow meter are checked. Multiplex Trio E fitting, electronic mixing unit 31 from 38...
  • Page 32: Troubleshooting

    Saved inlet time is set too short Set a longer inlet time Ä Chapter off too early. 3.3.2 „Setting the water inlet“ on page 26 Hot and cold water connections Exchange the connections mixed up Multiplex Trio E fitting, electronic mixing unit 32 from 38...
  • Page 33 Fully open the valves open Supply hoses kinked Check the laying of the supply hoses Filter clogged Clean the filter Motor for water flow not con‐ Check connection and function nected, or defective Multiplex Trio E fitting, electronic mixing unit 33 from 38...
  • Page 34: Care And Maintenance

    Normal soap or a mild cleaning agent can be used for regular care and prevention of lime scale on the control elements. Under no circum‐ stances should scouring agent or scratching objects be used. Multiplex Trio E fitting, electronic mixing unit 34 from 38...
  • Page 35: Maintenance

    72 hours, see Ä „Regula‐ tions from section: Maintenance“ on page 7 otherwise after 7 days at the latest, see Ä „Regulations from section: Maintenance“ on page 7 Multiplex Trio E fitting, electronic mixing unit 35 from 38...
  • Page 36: Changing The Filters In The Corner Valves

    3.5.4 Changing the battery The battery of the mixing unit should be replaced regularly because the mixing fitting cannot be used if the battery charge is below a specified minimum. Multiplex Trio E fitting, electronic mixing unit 36 from 38...
  • Page 37 Loosen the screws of the casing cover and retain. Remove the casing cover. Pull the plug straight away from the control to disconnect. Remove the battery from the mixing unit and dispose of properly. Multiplex Trio E fitting, electronic mixing unit 37 from 38...
  • Page 38: Disposal

    Place the casing cover in the mixing unit and re-fasten it. Disposal Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements. Multiplex Trio E fitting, electronic mixing unit 38 from 38...

This manual is also suitable for:

6146

Table of Contents