3.4.3

Cleaning the drain

Multiplex Trio F drain/overflow functional unit
If excessive limescale and contamination is found, use new insert
(model 6161.82)
Using multigrip pliers, insert the insert into the casing of the pipe
interrupter vertically from the front.
Insert the rosette into the shaft top.
The drain should be cleaned at regular intervals. The cleaning interval
depends on the use of the tub installation.
Proceed as follows to clean the drain:
Handling
23 from 25