Handling; Assembly Information; Mounting Conditions - Viega 8326.16 Instructions For Use Manual

Flush plate visign for public 5
Table of Contents

Advertisement

3

Handling

3.1

Assembly information

3.1.1

Mounting conditions

Installation position of the power pack
Flush plate Visign for Public 5
The model may only be used for the models mentioned in
2.3.1 'Areas of application' on page 6.
The power pack should be mounted in an easily accessible place to
allow subsequent access.
Before beginning to tile, a concealed socket should be installed for the
power pack with protective pipe to the cistern (installation set
Ä 'Optional accessories' on page 16).
If necessary, the power pack cable can be extended to a length of
4.75 metres (two extension cables
on page 16).
X3
X2
X1
Fig. 9: Installation position of the power pack
X1 max. 0.75 m
X2 max. 2.75 m with an extension cable (article number 628 505)
X3 max. 4.75 m with two extension cables (article number 628 505)
An extension of the mains supply by more than 5 metres
can lead to a situation in which the power is not sufficient
to actuate the flush.
Ä Chapter
Ä 'Optional accessories'
Handling
17