  • Page 1 Multiplex Trio F drain/overflow functional unit Instructions for Use for water inlet through the drain unit Model Year built: 6145.5 from 06/2015 en_INT...
  • Page 2 Multiplex Trio F drain/overflow functional unit 2 from 25...
  • Page 3: Table Of Contents

    Connecting the wastewater system 3.2.6 Connecting the inlet 3.2.7 Mounting equipment set 3.2.8 Leakage test Control Simple maintenance and cleaning pipe 3.4.1 Maintenance 3.4.2 Cleaning pipe interrupter 3.4.3 Cleaning the drain Disposal Multiplex Trio F drain/overflow functional unit 3 from 25...
  • Page 4: About These Instructions For Use

    This restriction does not extend to possible operating instructions. The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
  • Page 5: About This Translated Version

    German/European guidelines in this manual: The information is not binding for other countries and territories and should, as mentioned, be considered as support. Multiplex Trio F drain/overflow functional unit 5 from 25...
  • Page 6: Product Information

    The drain/overflow is suitable for bathtubs with a middle connection. Detailed information regarding all bathtub models and the corre- sponding Viega drains / overflows can be found in the catalogue or on the Internet. Product description 2.2.1...
  • Page 7 18 - profile seal 19 - O-ring 20 - fixing flange 21 - rotatable rosette 22 - pipe interrupter casing 23 - top of the pipe interrupter 24 - pipe interrupter rosette Multiplex Trio F drain/overflow functional unit 7 from 25...
  • Page 8: Technical Data

    It is possible to extend the odour trap below the bathtub in the case of bathtubs with a very thick floor. The extension set, model 6161.7, is available for such cases. Multiplex Trio F drain/overflow functional unit 8 from 25...
  • Page 9: Handling

    To ensure that no bath water flows back into the drinking water system, a pipe interrupter must be installed in the pipeline between the shut-off fitting and the bathtub inlet. The following schematic diagram shows what this should look like: Multiplex Trio F drain/overflow functional unit 9 from 25...
  • Page 10 It is important that the pipe interrupter is mounted vertically, in the direction of flow and at least 150 mm above the top edge of the bathtub. Observe the local standards and regulations. Multiplex Trio F drain/overflow functional unit 10 from 25...
  • Page 11: Installation Dimensions

    The following tools are required for mounting: fine-toothed saw mounting aid (included in the scope of delivery) Allen key (SW 3) Material No additional material is required for the complete mounting of the product. Multiplex Trio F drain/overflow functional unit 11 from 25...
  • Page 12: Assembly

    If necessary, observe the manufacturer's instructions. Push the union nut and clamping ring onto the pipe. Push Viega plug-in seat as far as it will go into the pipe. Euro cone connections are not compatible. Push the free end of the plug-in seat into the connection of the pipe interrupter.
  • Page 13 Mark drill holes. Drill holes. Screw on pipe interrupter with two crossed slot screws (size 4.5 or Encase the pipe interrupter and connection line in mortar. Tile the wall. Remove protective plug. Multiplex Trio F drain/overflow functional unit 13 from 25...
  • Page 14: Mounting Overflow

    Proceed as follows to the mounting of the overflow: Push the rubber sleeve onto the pipe of the overflow unit. The lower edge must be flush with the edge of the overflow pipe. Multiplex Trio F drain/overflow functional unit 14 from 25...
  • Page 15: Mounting The Drain

    Proceed as follows to mount the drain: Place the profile seal in the recess of the drain unit. Mount the drain unit with profile seal on the drain opening of the bathtub from below. Multiplex Trio F drain/overflow functional unit 15 from 25...
  • Page 16: Connecting Overflow And Drain

    The drain is securely mounted on the base of the bathtub. NOTICE! Connections where the pipes are not inserted far enough into each other become leaky. For this reason, maintain a minimum insertion depth of 15 mm for every connection. Multiplex Trio F drain/overflow functional unit 16 from 25...
  • Page 17: Connecting The Wastewater System

    The overflow and drain units are installed on the bathtub. The connection between overflow and drain has been made. If the wastewater pipe only has a diameter of 40 mm, cut off drain elbow. Ø40 Ø50 Multiplex Trio F drain/overflow functional unit 17 from 25...
  • Page 18: Connecting The Inlet

    Overflow and drain are mounted. Overflow and drain are connected. The connection to the wastewater system has been made. Remove the union nut of the connection elbow from the drain unit and remove connection elbow. Multiplex Trio F drain/overflow functional unit 18 from 25...
  • Page 19: Mounting Equipment Set

    Handling INFO! We show the mounting here with the Viega plug connec- tion. Mounting can also be carried out with other connecting materials. If necessary, observe the manufacturer's instructions. Push union nut and clamping ring (parts of the connection set) onto the water-carrying pipe.
  • Page 20: Leakage Test

    The leakage test is only carried out as a visual inspection. Check drain/overflow fitting for visible leaks. Control The drain / overflow are controlled via the rotatable rosette on the over- flow. Proceed as follows to open or close the drain: Multiplex Trio F drain/overflow functional unit 20 from 25...
  • Page 21: Simple Maintenance And Cleaning Pipe

    Strong stains, even around the drain unit and the siphon, can be removed using typical household cleaner. It should be noted that the cleaning agent should be rinsed off after the prescribed soaking time. There should be no residue on the components. Multiplex Trio F drain/overflow functional unit 21 from 25...
  • Page 22: Cleaning Pipe Interrupter

    Proceed as follows to clean or replace the insert with the membrane: Remove rosette. Pull the insert out of the casing using multigrip pliers. If there is only a little limescale and contamination, rinse the insert carefully. Multiplex Trio F drain/overflow functional unit 22 from 25...
  • Page 23: Cleaning The Drain

    Insert the rosette into the shaft top. 3.4.3 Cleaning the drain The drain should be cleaned at regular intervals. The cleaning interval depends on the use of the tub installation. Proceed as follows to clean the drain: Multiplex Trio F drain/overflow functional unit 23 from 25...
  • Page 24 Clean inlet element by holding it under running water. Do not use any sharp or pointed objects when cleaning as this could damage the material. Loosen the Allen screw of the valve cone with an Allen key (size 3). Multiplex Trio F drain/overflow functional unit 24 from 25...
  • Page 25: Disposal

    Place a new seal in the recess in the valve cone. Only use original replacement seals from Viega (model 6162-268), which are intended for the valve cone. If necessary, clean drain casing with running water and a mild cleaning agent.