3.2.4

Connecting overflow and drain

Multiplex Trio F drain/overflow functional unit
Select suitable valve top:
Use the B = 22.5 mm high flat valve top for steel tubs with wall
thickness A = 2–11 mm.
Use the B = 30 mm high valve top for plastic tubs with wall thick-
ness A = 11–16 mm.
Apply lubricant to the inside of the seal and place onto the under-
side of the valve top.
Install the valve top into the drain unit and screw together with the
mounting aid.
The mounting aid must be placed on the screw recesses with the
holes on the underside.
After the overflow and the drain have been mounted, you must connect
them both using the overflow pipe. Proceed as follows:
Requirements:
The overflow is mounted in the overflow opening.
n
The drain is securely mounted on the base of the bathtub.
n
NOTICE! Connections where the pipes are not inserted far
enough into each other become leaky. For this reason, maintain
a minimum insertion depth of 15 mm for every connection.