Specifications - Santak K Series User Manual

Table of Contents

Advertisement

If only the current value is marked, multiply the rated voltage by
the power factor and convert it to W.
If you find the battery is poor (for example: battery power is greatly
reduced), it should be replaced, please contact the distributor. Make
sure that the new battery parameters must be the same as the
specifications (see Specification data).
The Caution!
Non-professional personnel Do not open the cover to avoid the risk of
electric shock.
The Caution!
Do not open the battery to prevent the electrolyte from harming the
human body.

Specifications

Model
INPUT
Voltage
Frequency
OUTPUT
Voltage(Normal Mode)
Frequency(Normal
Mode)
Voltage(Battery Mode)
Frequency(Battery
Mode)
Transfer Time
Waveform
CAPACITY *
PROTECTION
Full protection
ENVIRONMENT
Humidity
Noise Level
BATTERY
Type & Number
Backup time*
Charging Time
Dimension
Net weight
K500
162×(1±7%)VAC~268×(1±7%)VAC
Follow AC input frequency
50Hz±1Hz or 60Hz±1Hz
500VA / 300W
Discharge, overcharge and overload protection
20%-90 % RH @ 0° to 40° C (non-condensing)
12Vx1
12 hours recover to 90% capacity
98mm×280mm×150mm
4.4kg
1
K series
>40Hz
220×(1±15%)VAC
220×(1±10%)VAC
≤10ms
Modified Sine Wave
1000VA / 600W
Less than 40dB
≥6min(half load)
133mm×320mm×190mm
K1000
12Vx2
9.0kg

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

K1000K500

Table of Contents