Excessive Condensate - Dixie Narco 90 Series Operation Manual

Single price / siid e-model venders
Hide thumbs Also See for 90 Series:
Table of Contents

Advertisement

WHAT TO CHECK
1. Is the door sealed properly?
(This can be checked by inserting a piece of paper, thin plastic, or
paper currency between the cabinet and the door seal when the
main door is open. When the door is closed properly the paper
should exert some resistance as it is pulled out.)
YES, go to step 4.
2.
Is the motor cover interfering with the inner door?
NO, go to step 3.
3.
Has the machine been vandalized?
NO, go to step 4.
4.
Are the drain pan soakers positioned properly?
YES
5.
Is the drain hose positioned properly?
YES
6.
Are there fourteen fiberglass soakers in the pan?
YES
7.
Are the condensate & evaporator free from obstruction?
YES
8.
Is the delivery door misaligned?
NO
9. Consult the Dixie-Narco Factory Service at
1-800-688-9090.
Note: Have the vender model and serial number available.
Page 75 of 72
SYMPTOM: EXCESSIVE CONDENSATE
SOLUTION
1. NO, Ensure the door is closed tightly. If door
still does not seal properly, see step 2.
2. YES, reinstall the motor cover properly.
3. YES, replace necessary components.
4. NO, place soakers upright in pan so that air will
flow over and through the soakers..
5. NO, place the drain hose in the drain pan along
side of the soakers. Ensure the drain hose is not
clogged.
6. NO, place fourteen fiberglass soakers in the
condensate pan.
7. NO, remove all debris and/or cans from the area
around the evaporator and condenser. Clean the
evaporator and condenser coils with a stiff brush
or compressed air.
8.
YES,
A. Level the vender properly.
B. Align the inner and outer doors so that
the delivery door does not stick open.
9. Consult the Dixie-Narco Factory Service at
1-800-688-9090.
Note: Have the vender model and serial number
available.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dncb 276eDncb 501eDncb 600e

Table of Contents