Siid Coin / Currency - Dixie Narco 90 Series Operation Manual

Single price / siid e-model venders
Hide thumbs Also See for 90 Series:
Table of Contents

Advertisement

9.
Problem:
No motors work.
Troubleshooting:
10. Problem:
F2 Motor Power fuse continuously blows.
Troubleshooting:
1.
Problem:
Will not accept coins or bills.
Troubleshooting:
2.
Problem:
Validator sometimes sets up credit and then steals bill.
Troubleshooting:
3.
Problem:
Accepts coins and displays, but will not vend.
Troubleshooting:
4.
Problem:
Incorrect change paid back, use correct change lamp stays on.
Troubleshooting:
5.
Problem:
Cannot dump coins when in "Cd" mode or "CPO" mode.
Troubleshooting:
board.
6.
Problem:
BA30 stealing bills.
Troubleshooting:
Set-up subject to change without notice. For packages not listed contact Dixie-Narco Factory
Service at (800) 688-9090.
A)
Check F2 motor power fuse (6 amp).
B)
Check lamp and lamp wiring for broken, backed out, or crossed wires.
C)
Check ballast and ballast wiring for broken, backed out, or crossed wires.
A)
Check if 6 amp fuse is used.
B)
Check that capacitor instead of MOV used at CR1 location.
C)
Check ohms of each motor in off state
- unplug wires to coil of motor.
- ohms should be 6.5, if less coil of motor has a short.
D)
Check motor harness.
E)
Check motor extension harness.
F)
Check for bad bulb in lighting system.

SIID COIN / CURRENCY

A)
Check coin return lever is not pressed.
B)
Check F3 peripheral (1.0 Amp) fuse.
C)
Go to diagnostics and test.
1.
Will not take coins, replace coin mech.
2.
Still will not take coins, check connections and mech harness.
D)
Check for bad connections or broken, backed out, or crossed wires from validator/changer to
control board.
E)
With Mars 6510 Mdb mechs, serialized prior to 176xxxxxxxx that do not have a red dot on
the coin mech, check the coin mech.
F)
Check control board.
A)
Check for proper interface harness.
B)
Check for bad connections or broken, backed out, or crossed wires from vend/sold-out
harness.
C)
Check validator.
D)
Check control board.
A)
Check coin mech.
B)
Check for bad connections or broken, backed out, or crossed wires from validator/changer to
control board.
C)
Check voltage supply (110-115AC) at outlet.
D)
Check control board.
A)
Check control board.
A)
Check for bad connections or broken, backed out, or crossed wires from changer to control
B)
Check select switches and wiring.
C)
Check coin mech.
D)
Ensure you are not using Mars International Executive or NRI Simplex changers.
E)
Check voltage supply (110-115AC) at outlet.
F)
Check control board.
A)
Check door switch.
B)
Check validator.
Page 42 of 72

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dncb 276eDncb 501eDncb 600e

Table of Contents