7.5.1.3 Setting Feature Parameters

Procedure
Step 1 Choose Function Menu > Settings > Feature Parameters to set feature parameters.
Figure 7-10 Feature parameters
Table 7-4 Feature parameters
Parameter
MPPT multi-peak
scanning
MPPT multi-peak
scanning interval
(min)
Issue 04 (2019-06-30)
Description
When the SUN2000 is used in scenarios where
PV strings are obviously shaded, enable this
function. Then the SUN2000 will perform
MPPT scanning at regular intervals to locate the
maximum power.
The scanning interval is set by MPPT
multi-peak scanning interval.
Specifies the MPPT multi-peak scanning
interval.
This parameter is displayed only when MPPT
multi-peak scanning is set to Enable.
Copyright © Huawei Technologies Co., Ltd.
7 Man-Machine Interactions
Value Range
Disable
Enable
[5, 30]