Huawei SUN2000-63KTL-JPH0 User Manual page 43

Hide thumbs Also See for SUN2000-63KTL-JPH0:
Table of Contents

Advertisement

SUN2000-63KTL-JPH0
User Manual
Figure 5-2 SUN2000 cable connections (dashed box indicating optional components)
Table 5-1 Component description
No.
Component
A
SmartLogger
B
AC switch
C
PV string
Issue 04 (2019-06-30)
To ensure the system response speed, you are advised to connect less than 30 cascading
SUN2000s on each COM port of the SmartLogger2000.
The RS485 communication distance between the SUN2000 at the end and the
SmartLogger2000 cannot exceed 1000 m.
Remarks
The SUN2000 can connect to the
SmartLogger2000 to implement RS485
communication.
Copyright © Huawei Technologies Co., Ltd.
Installed in the AC combiner box
Recommended: a three-phase AC circuit
breaker with a rated voltage greater than
or equal to 550 V AC and a rated current
of 100 A
A PV string is composed of PV modules
connected in series.
The SUN2000 supports the input from 12
PV strings.
5 Electrical Connections
Source
Can be purchased
from Huawei
Prepared by the
customer
Prepared by the
customer
36