2.4 Working Principles

2.4.1 Circuit Diagram

The SUN2000 receives inputs from 12 PV strings. The inputs are grouped into 6 MPPT
circuits inside the SUN2000 to track the maximum power point of the PV strings. The DC
power is then converted into three-phase AC power through an inverter circuit. Surge
protection is supported on both the DC and AC sides.
Issue 04 (2019-06-30)
Copyright © Huawei Technologies Co., Ltd.
Name
Meaning
DC terminal
High voltage exists after the
operation
SUN2000 is powered on. To
warning
avoid electric shocks,
perform the following system
power-off operations before
plugging or unplugging DC
input connectors of the
SUN2000:
1. Send a shutdown
2. Turn off the downstream
3. Turn off the two DC
Spot-check
terminal
operation
warning
SUN2000 SN
Indicates the SUN2000 serial
label
number.
Weight label
The SUN2000 needs to be
carried by four persons or
using a pallet truck.
2 Overview
command.
AC switch.
switches at the bottom.
Exercise caution when
operating spot-check
terminals because they are
always energized.
Disconnect the DC
switches 1 and 2 before
performing the dielectric
withstand voltage test
through the PV1+ to
PV12+ and PV1- and
PV12- ports.