Noraxon Ultium EMG Analog Input SmartLead User Manual

Biomechanics research system

Advertisement

Quick Links

Analog Input SmartLead
Ultium
Biomechanics
Research System
Analog Input
SmartLead User Manual
P-811 Rev B (May 2019)
1

Advertisement

Table of Contents
loading

Summary of Contents for Noraxon Ultium EMG Analog Input SmartLead

  • Page 1 Analog Input SmartLead Ultium Biomechanics ™ Research System  Analog Input SmartLead User Manual P-811 Rev B (May 2019)
  • Page 2: Table Of Contents

    Analog Input SmartLead Table of Contents 1 Introduction ................................5 1.1 Analog Input SmartLead Brief Description ..................5 1.2 Contradictions ............................5 Section 2: Definitions ............................5 1.2 Glossary of Terms ............................6 3 Identifications ..............................6 3.1 Model Designation ...........................6 3.2 Product Versions and Configurations ....................6 4 General Warning and Cautions ........................7 4.1 Risks and Benefits ............................7 4.2 Safety Information Summary .........................7...
  • Page 3 Analog Input SmartLead 15.1 Expected Useful Lifetime ........................26 15.2 Technical Specifications ........................26 15.3 Environmental Conditions for Storage and Transport ..............27 15.4 Ultium Analog Input SmartLead Operation ..................27 P-811 Rev B (May 2019)
  • Page 4 Noraxon and myoRESEARCH are registered trademarks and the Noraxon logo, myoANALOG, myoFORCE, myoMETRICS, myoMOTION, myoMUSCLE, myoPRESSURE, myoVIDEO, myoSYNC, NiNOX, TRUsync and Ultium are common-law trademarks of Noraxon U.S.A., Inc. All other trademarks are the property of their respective owners. ©2018, all rights reserved.
  • Page 5: Introduction

    The Ultium Universal Analog Input Probe SmartLead is an accessory to the Ultium EMG sensor (#810) which accepts non-Noraxon sensors within the specifications required for the Analog Input Probe. This probe gives users the freedom to select the appropriate sensor for their application.
  • Page 6: Glossary Of Terms

    Analog Input SmartLead 1.2 Glossary of Terms Ultium Sensor -- A small individual radio transmitter typically worn on the body used to measure and transmit bio-potential signals (such as EMG) or motion related signals (such as acceleration). The Ultium Systems can accommodate up to 16 body worn Ultium Sensors in one network. Two Ultium Systems may be used in parallel, on separate RF networks, to accommodate up to 32 body worn sensors.
  • Page 7: General Warning And Cautions

    Analog Input SmartLead For additional equipment details refer to Section 9 of this manual. As the Noraxon Systems require software to perform its function, the equipment is offered in combination with the following computer program packages: Part# 402 MR3 myoMuscle Module 4 General Warning and Cautions 4.1 Risks and Benefits...
  • Page 8: Getting Started

    Analog Input SmartLead 5 Getting Started 5.1 Quick Start Guides Please see the hardware manual for the appropriate EMG system. P-880: Ultium hardware user manual 6 Preparing the Product for Use 6.1 Unpacking and Component Identification Ultium FootSwitch SmartLead with 2.5mm TRRS Mating Connector (Part #802) Ultium FootSwitch SmartLead with Exposed Input Wires (Part #802)
  • Page 9: Signal Source Setup

    Analog Input SmartLead Charger Contacts – Sensor battery is charged, and sensor data is exchanged through these points. Serial Number – Unique 5- character serial number which identifies each EMG sensor. 3. Analog Input SmartLead Serial Number: Unique 5-character serial number which identifies each SmartLead.
  • Page 10 Analog Input SmartLead 2) When utilizing the Analog Input SmartLead version with the 2.5 mm TRRS Mating Connector (For more information refer to Section 9 of this manual), one may utilize the following diagram for assistance soldering personal circuitry to the connector: Input Number Relation to Pole Number Input 1 Pole 1...
  • Page 11: Component Interconnections

    Analog Input SmartLead Attention • The Ultium Analog Input SmartLead (both versions) provides a single, shared Ground wire. The operator must ensure that the system they are attaching to is compatible with this configuration. 6.4 Component Interconnections Analog Input SmartLead: 2.5mm TRSS Mating Connector Version: Step 1A Connect the Ultium Sensor to the Ultium Analog Input...
  • Page 12: Device Communication (Driver) Software Installation

    Analog Input SmartLead Yellow, see the Troubleshooting section of this manual. Connect the Ultium Analog Input Step 1B SmartLead to the desired circuitry (see below: Signal Source Setup). 6.5 Device Communication (Driver) Software Installation No driver installation is needed. The Ultium Receiver communicates over the USB port. P-811 Rev B (May 2019)
  • Page 13: Companion Software Installation

    MR3 software. 6.7 Companion Software Configuration Before the Ultium Analog Input SmartLead can be used with the Noraxon Ultium system, the companion software must be configured to recognize the different components that make up the system.
  • Page 14 Analog Input SmartLead 6.7.1 MR3 Configuration Step 1 Enter the Hardware Setup screen and setup the Noraxon EMG system in accordance with its provided hardware manual. Step 2 Click ‘Detect Sensors in Charger’ (All sensors which you would like to use must be in the charger) –...
  • Page 15 Analog Input SmartLead Step 3 Once back in the Home screen, choose if you would like to create a new configuration or edit an existing configuration. Step 4 In the measurement setup screen, insert the Ultium system into the Devices of your configuration box.
  • Page 16 ** Step 5b Continue with the measurement setup as described in the Noraxon system’s hardware manual. 6.7.2 Find My Sensor Feature Allows the user to quickly locate a specified Ultium sensor while creating/editing a MR3 configuration (refer to section 7 for guidance on how to create or edit a configuration).
  • Page 17 Analog Input SmartLead in bursts of 3. If the topmost star is clicked, every sensor that is currently in the configuration will execute the same blinking pattern. If a SmartLead is connected to a sensor when the sensors are detected in the MR3 hardware setup (Section 6 ->...
  • Page 18 Analog Input SmartLead Once the sensors have been selected, double click on the sensor type for the desired Analog Input channel, then select the desired sensor type. P-811 Rev B (May 2019)
  • Page 19: Pre-Use Check-Out

    Analog Input SmartLead 7 Pre-Use Check-Out 7.1 Normal Appearance of Signals The sensor’s STATUS LED provides a means of communicating its operational state. In the idle state, the STATUS LED will flash blue at a low, once per second rate. When the sensor is actively measuring a signal, the STATUS LED will flash recognizably faster (green).
  • Page 20: Operating Instructions

    Never use the Noraxon Ultium System on a person with an implanted pacemaker • Never operate the Noraxon Ultium System within 1 meter of any critical medical device 8.2 Normal Functions with Interface to a PC When used with the companion software, the Analog Input SmartLead displays and records signals...
  • Page 21: Exceptional Functions/Situations (Error Messages)

    Analog Input SmartLead 8.3 Exceptional Functions/Situations (error messages) Please see the appropriate Ultium hardware manual (P-880) for possible error messages. 8.4 Shutdown after Use At the end of the day: • Place all EMG sensors inside the sensor docking station(s). •...
  • Page 22: Accessories And Optional Modules

    Analog Input SmartLead 9 Accessories and Optional Modules 9.1 Accessories The Analog Input SmartLead is either open wired (displayed in Section 6 – no accessories) or used in conjunction with a 2.5 mm TRRS Mating Connector as displayed below. 10 Cleaning 10.1 Safety Precautions When Cleaning WARNING Only use a damp cloth with mild soap and water or isopropyl alcohol to clean the Ultium...
  • Page 23: Maintenance By Qualified Individuals

    11.3 Companion Software Updates • Perform a backup of the data folders to a separate drive as a precaution. • Click on the Patch/Update link provided in the email or as given on the Noraxon website. • Download the Patch/Update file. •...
  • Page 24: Website Link To Faq

    MR3 and run a firmware update if needed. 12.1 Website Link to FAQ Answers to common questions can be found at Noraxon’s Frequently Asked Questions (FAQ) website page at this link: https://www.noraxon.com/support-learn/technical-support/faqs/ Other educational material is available at this link: https://www.noraxon.com/support-learn/technical-support/...
  • Page 25: Service And Repair

    SmartLeads, where applicable. 13.2 Warranty Information Noraxon equipment including optional items is guaranteed to be free from defects in material and workmanship for 1 year from the date of purchase. The warrant period begins on the date of product shipment from Scottsdale, Arizona.
  • Page 26: Spare Parts And Consumables

    If you are shipping from outside the USA please use UPS, FedEx, DHL, or EMS (US Postal Service) and not a freight-forwarder. Using a freight-forwarder incurs additional brokerage fees. If a package is shipped to Noraxon via a carrier other than the ones listed above, it may be refused. 14 Spare Parts and Consumables 14.1 Consumable Items...
  • Page 27: Environmental Conditions For Storage And Transport

    The device must be self-powered because the sensor does not provide power to the device attached to it. The input range of the SmartLead was initially +/-5V. However, Noraxon has increased this to +/- 20V in later revisions. Be sure to check the label on the connector of the SmartLead before measuring signals larger than +/-5V.
  • Page 28 Analog Input SmartLead The input stages of the 3 input channels include resistor dividers. This creates an input impedance of 2.1 Mohms. P-811 Rev B (May 2019)