Noraxon Ultium EMG Analog Input SmartLead User Manual page 17

Biomechanics research system
Table of Contents

Advertisement

Analog Input SmartLead
in bursts of 3. If the topmost star is clicked, every sensor that is currently in the configuration will
execute the same blinking pattern.
If a SmartLead is connected to a sensor when the sensors are detected in the MR3 hardware setup
(Section 6 -> MR3 Configuration) it will override the EMG functionality of that sensor. Therefore, if
the SmartLead is moved to a new sensor, Step 1-5 of Section 6 (MR3 Configuration) must be
recompleted.
To check if the SmartLeads are currently connected to the proper Ultium sensor, the Find My
Sensor feature may be useful. Click the topmost star (shown in the above figure). If all lights blink
(white color), then they are properly connected. If one of the sensors blinks (red color), the
SmartLead that is connected to this sensor should be connected to another sensor. It is
recommended to recomplete Steps 1-5 of Section 6 above if this does occur.
6.7.3 Custom User-Defined Channel Types
When using the Analog Input SmartLead, it may be of interest to customize the settings (Units,
Minimum Voltage, Maximum Voltage, Resolution, etc.) for the signal that is to be analyzed.
This can be done within the configuration setup (Step 3-5: Section 6). Select 'User Defined Sensors'
– demonstrated in the image below. To edit the settings, select 'Insert/Delete Sensors.
P-811 Rev B (May 2019)
17