KONTURflex specifications
Settings on the MA
• CANopen address is freely selectable
• Device selection switch at position "0"
Settings on the CANopen
• Produced/Consumed data settings:
Dependent on number of beams used, but at least "8 bytes In"
• User Parameters:
"Transparent Mode", "Use EDS Settings", Baudrate 38400, "8 Data Bits", "No parity",
"2 Stop Bits"
KONTURflex settings
First, the following settings are to be performed on the device using KONTURFlex-Soft:
• Either "Autosend (fast)" or "Autosend with data in Modbus format"
• Repeat time "31.5ms"
• Autosend baud rate "38.4KB"
• 2 stop bits, no parity
Leuze electronic
235i
MA
Specifications for Leuze end devices
235i
81