Leuze electronic MA 235i Operating Instructions Manual page 69

Fieldbus gateway canopen
Table of Contents

Advertisement

12.4.6.6 Object 3000
The object describes the function mode of the MA 235i.
Index
Sub-
index
(hex)
(hex)
3000
--
Parameter value:
0 = Transparent Mode
1 = Collective Mode
12.4.6.7 Object 3001
The object describes the serial RS 232 settings of the MA 235i.
Index
Sub-
index
(hex)
(hex)
3001
--
01
02
03
04
05
Use Rotary Switch
Parameter value:
0 = use rotary switch (default)
1 = use EDS settings
RS 232 Baud Rate
Parameter value:
3 = 300
6 = 600
12 = 1200
24 = 2400
48 = 4800
96 = 9600 (default)
192 = 19200
384 = 38400
576 = 57600
1152= 115200
Leuze electronic
Serial Line Mode
h
Name
Data type
Data Mode
u32
Serial Settings
h
Name
Data type
Serial
u32
Settings
Use Rotary
u32
Switch
Baud Rate
u32
Data Bits
u32
Parity
u32
Stop Bits
u32
Commissioning and configuration
Access
Value range
Minimum
rw
--
Access
Value range
Minimum
rw
--
rw
--
rw
--
rw
--
rw
--
rw
--
MA
235i
Maximum
Default
Transparent
--
Mode (0)
Maximum
Default
--
Use Rotary
--
Switch (1)
9600 Baud
--
(96)
--
8 Data Bits (8)
--
None (1)
--
1 Stop Bit (1)
Remark
Remark
67