Electrical Connection; Pwr In - Voltage Supply / Switching Input/Output - Leuze electronic MA 235i Operating Instructions Manual

Fieldbus gateway canopen
Table of Contents

Advertisement

Electrical connection

7.2
Electrical connection
The MA
235i
The voltage supply (PWR IN) as well as the switching inputs/outputs (PWR OUT or PWR IN)
are connected there. The number and function of the switching inputs/outputs is dependent
on the connected end device. Two additional M12 connectors/sockets are used for connec-
tion to the fieldbus. Both of these connections are A-coded.
An internal RS 232 interface is used for connecting the respective Leuze device. Another
internal RS 232 interface functions as a service interface for configuring the connected
device via a serial null modem cable.
PWR IN
SWIO_2
2
GND
3
5
4
FE
SWIO_1
M12 connector
(A-coded)
Figure 7.2:
Described in detail in the following are the individual connections and pin assignments.
Attention!
Voltage supply and bus cable are coded in the same way. Please observe the printed
connection designations
7.2.1
PWR IN – voltage supply / switching input/output
PWR IN
SWIO_2
GND
3
FE
SWIO_1
M12 connector
(A-coded)
Table 7.1:
28
features two M12 connectors/sockets for voltage supply; each is A-coded.
PWR OUT
SWIO_2
2
VIN
1
VOUT 1
3
5
4
SWIO_1
M12 socket
(A-coded)
MA 235 connections
PWR IN (5-pin connector, A-coded)
2
VIN
1
5
4
Thread
PWR IN pin assignment
LEUZE Device
GND
FE
Pin
Name
1
VIN
2
SWIO_2
3
GND
4
SWIO_1
5
FE
FE
MA
235i
HOST / BUS IN
CAN_H
4
CAN_L
5
DRAIN
V-
1
3
2
V+
M12 connector
(A-coded)
Remark
Positive supply voltage +18 ... +30VDC
Switching input/switching output 2
Negative supply voltage 0VDC
Switching input/switching output 1
Functional earth
Functional earth (housing)
BUS OUT
CAN_H
CAN_L
4
5
3
V-
1
DRAIN
2
V+
M12 socket
(A-coded)
Leuze electronic