COVER AND YOKE TIPS
COMPLAINT
Cover hard to CLOSE
Cover won't OPEN
Never use force to OPEN
cover.
O-ring Break
DO NOT
rest basket on
top flange of cooking well.
Damage to area in con-
tact with o-ring can cause
leaking under pressure or
0-ring failure.
Pressure Gauge does not
indicate rising pressure
when exhaust valve is
closed.
PRESSURE SYSTEM TIPS
DO NOT
nent when there is pressure in the cooking well. Hot oil could spray out
under pressure causing serious burns.
COMPLAINT
No pressure
Excess pressure
CAUSE
1. O-ring dry or dirty
2. O-ring groove dirty
3. Hard O-ring
1. O-ring dry or dirty
2. O-ring groove dirty
3. Hard O-ring
4. Pressure not released
5. Pressure regulating valve
out of adjustment
1. O-ring groove dirty
2. Nicks in cooking well or
cover
1. Port is plugged
2. Pressure gauge is dam-
aged
attempt to tighten, repair or replace any fitting, line or compo-
CAUSE
1. Pressure regulating valve
OPEN
2. Pressure regulating valve
dirty or blocked open
3. Leaks around cover O-
ring
10-4
broaster.com Manual #17270 10/13 Rev 12/14
REMEDY
1. Clean and lubricate
2. Clean
3. Replace
1. Clean and lubricate
2. Clean
3. Replace
4. OPEN pressure regulating
valve
5. Contact service person
1. Clean
2. Remove
1. Clean port on bottom of
cover
2. Replace pressure gauge
REMEDY
1. CLOSE
2. Contact service person
3. Replace O-ring
1. Turn power switch OFF.
Contact service person.