COVER AND YOKE TIPS
COMPLAINT
Cover hard to CLOSE
Cover won't OPEN
Never use
force to
OPEN cover.
O-ring Break
DO NOT
rest basket
on top flange of cooking
well. Damage to area in
contact with o-ring can
cause leaking under pres-
sure or 0-ring failure.
Pressure Gauge does not
indicate rising pressure
when exhaust valve is
closed.
PRESSURE SYSTEM TIPS
DO NOT
when there is pressure in the cooking well. Hot oil could spray out under
pressure causing serious burns.
COMPLAINT
No pressure
Excess pressure
CAUSE
1. O-ring dry or dirty
2. O-ring groove dirty
3. Hard O-ring
1. O-ring dry or dirty
2. O-ring groove dirty
3. Hard O-ring
4. Pressure not released
5. Pressure regulating valve
out of adjustment
1. O-ring groove dirty
2. Nicks in cooking well or
cover
1. Port is plugged
2. Pressure gauge is dam-
aged
attempt to tighten, repair or replace any fitting, line or component
CAUSE
1. Pressure regulating valve
OPEN
2. Pressure regulating valve
dirty or blocked open
3. Leaks around cover O-
ring
broaster.com Manual #16284 8/05 Rev 1/14
1. Clean port on bottom of
2. Replace pressure gauge
12-4
REMEDY
1. Clean and lubricate
2. Clean
3. Replace
1. Clean and lubricate
2. Clean
3. Replace
4. OPEN pressure regulating
valve
3. Contact service person
1. Clean
2. Remove
cover
REMEDY
1. CLOSE
2. Contact service person
3. Replace O-ring
1. Turn cook/filter switch
OFF. Contact service
person.