9. Install new element (8) in reverse order.
Use new O-rings (17) located between
element and inside of the cooking well.
10. Install large element nut and tighten.
11. Be sure all wire connections are
secure and in their original location.
LIMIT SWITCH
When the pressure regulating valve is
CLOSED, switch supplies power to the tim-
ing circuit.
Adjustment:
Replacement:
4-5
broaster.com Manual #17270 1013 Rev 12/14
1. See ACCESS FOR SERVICE.
2. With needle nose pliers, disconnect
one wire from the switch (15).
3. CLOSE pressure regulating valve.
Check between remaining wire and
terminal where other wire was discon-
nected with an ohmmeter. Meter
should indicate a closed circuit. If not,
mounting bracket is out of adjustment
or switch is faulty.
1. With pliers, bend mounting bracket
(16) closer or further away from control
rod.
1. See ACCESS FOR SERVICE.
2. Remove wires from switch.
3. Remove two mounting screws.
4. Install new switch in reverse order. Be
sure all wire connections are secure
and in their original location.