FLAME ADJUSTMENTS
Gas Pressure Adjustment:
Always check gas pressure after a new gas
valve installation. Check pressure when
other gas equipment is also operating. This
will ensure adequate pressure during peak
operating times.
There is a pressure tap in output side of the
gas valve for manometer hook-up. Correct
output gas pressures, in Water Column, are:
Natural Gas:
Propane Gas: 10.0" W.C.
1. Turn cook/filter switch, manual gas
shut off valve (1) and switch (2) OFF.
2. Remove pressure tap (7) on gas valve.
3. Install manometer.
4. Turn gas shut off valve (1) ON.
5. Light pilot see MODEL 1800GH
LIGHTING INSTRUCTIONS. Turn gas
valve switch (2) ON.
Check cooking oil level
before turning power switch
on .
6. Turn cook/filter switch to COOK.
3.5" W.C.
broaster.com Manuals #17270 10/13 Rev 12/14
7. Remove regulator adjustment cover
(8). Adjust pressure when main burner
is on.
8. Turn cook/filter switch, manual gas
shut off valve (1) and switch (2) OFF.
9. Remove manometer. Replace pres-
sure tap plug. Use gas pipe sealer on
threads.
10. Turn manual gas shut off valve (1) ON.
11. Slide gas valve switch (2) ON.
12. Turn cook/filter switch to COOK.
13. Check pressure tap with a soap and
water solution when main burner is on.
Bubbles indicate a gas leak.
Pilot Burner Flame Adjustment:
Pilot burner flame must surround sensor (9).
1. Remove screw (10).
2. Adjust flame and replace screw.
8-4